PMID- 11404844 OWN - NLM STAT- MEDLINE DCOM- 20010809 LR - 20131121 IS - 0951-4198 (Print) IS - 0951-4198 (Linking) VI - 15 IP - 13 DP - 2001 TI - Evaluation of several solid phase extraction liquid chromatography/tandem mass spectrometry on-line configurations for high-throughput analysis of acidic and basic drugs in rat plasma. PG - 1075-83 AB - Several configurations using 6- and 10-port switching valves were studied for high flow, on-line extraction of rat plasma coupled to an electrospray triple quadrupole mass spectrometer. Each plasma sample was diluted 1:1 with an aqueous internal standard solution. The sample was injected into a 2.1 x 20 mm cartridge column packed with 25 microm divinylbenzene/N-vinylpyrrolidone packing using 100% aqueous mobile phase at 4 mL/min. After sample loading and sample cleanup, the analytes were eluted from the extraction column with a 1.0-min gradient at 0.4 mL/min. The samples were either analyzed directly after elution from the extraction column or after additional separation using a short high performance liquid chromatography (HPLC) column. The different configurations were tested using an acidic drug (diflunisal) and a basic drug (clemastine) in rat plasma. On-line analysis was performed by injecting 200 microL of diluted plasma. The mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. All calibration standards gave relative standard deviations (RSDs) below 5%. The total time per sample was 3 min. CI - Copyright 2001 John Wiley & Sons, Ltd. FAU - Mallet, C R AU - Mallet CR AD - Waters Corporations, 34 Maple St., Milford, MA 01757-3696, USA. claude_mallet@waters.com FAU - Mazzeo, J R AU - Mazzeo JR FAU - Neue, U AU - Neue U LA - eng PT - Journal Article PL - England TA - Rapid Commun Mass Spectrom JT - Rapid communications in mass spectrometry : RCM JID - 8802365 RN - 0 (Indicators and Reagents) RN - 4U5MP5IUD8 (Niflumic Acid) RN - 7C546U4DEN (Diflunisal) RN - 95QN29S1ID (Clemastine) RN - DAA13NKG2Q (Papaverine) SB - IM MH - Animals MH - Chromatography, High Pressure Liquid/instrumentation/methods MH - Clemastine/*blood MH - Diflunisal/*blood MH - Equipment Design MH - Indicators and Reagents MH - Niflumic Acid/*blood MH - Online Systems MH - Papaverine/*blood MH - Rats MH - Reproducibility of Results MH - Sensitivity and Specificity MH - Spectrometry, Mass, Electrospray Ionization/instrumentation/methods EDAT- 2001/06/19 10:00 MHDA- 2001/08/10 10:01 CRDT- 2001/06/19 10:00 PHST- 2001/06/19 10:00 [pubmed] PHST- 2001/08/10 10:01 [medline] PHST- 2001/06/19 10:00 [entrez] AID - 10.1002/rcm.346 [doi] PST - ppublish SO - Rapid Commun Mass Spectrom. 2001;15(13):1075-83. doi: 10.1002/rcm.346.