PMID- 15468860 OWN - NLM STAT- MEDLINE DCOM- 20041213 LR - 20131121 IS - 0300-5283 (Print) IS - 0300-5283 (Linking) VI - 59 Suppl B DP - 2004 May TI - Tensile strength and water absorption of alumina filled poly (methyl methacrylate) denture base material. PG - 145-6 AB - The aim of this study was to evaluate the tensile properties and water absorption of denture base material prepared from high molecular weight poly methyl methacrylate (PMMA) and alumina (Al2O3) as particulate filler. Specimens for mechanical testing were prepared by adding composite powder to the monomer followed by hand mixing as in dental laboratory procedure. The tensile strength of the prepared denture base material was slightly higher than commercial denture base material, while the water absorption was almost the same for all formulation of denture base materials. FAU - Nizam, A AU - Nizam A AD - School of Medical Sciences, Universiti Sains Malaysia. FAU - Mohamed, S H AU - Mohamed SH FAU - Arifin, A AU - Arifin A FAU - Mohd Ishak, Z A AU - Mohd Ishak ZA FAU - Samsudin, A R AU - Samsudin AR LA - eng PT - Comparative Study PT - Journal Article PT - Research Support, Non-U.S. Gov't PL - Malaysia TA - Med J Malaysia JT - The Medical journal of Malaysia JID - 0361547 RN - 059QF0KO0R (Water) RN - 9011-14-7 (Polymethyl Methacrylate) RN - LMI26O6933 (Aluminum Oxide) SB - IM MH - Absorption MH - *Aluminum Oxide MH - *Denture Bases MH - Humans MH - Polymethyl Methacrylate/*chemical synthesis MH - Tensile Strength MH - Water EDAT- 2004/10/08 09:00 MHDA- 2004/12/16 09:00 CRDT- 2004/10/08 09:00 PHST- 2004/10/08 09:00 [pubmed] PHST- 2004/12/16 09:00 [medline] PHST- 2004/10/08 09:00 [entrez] PST - ppublish SO - Med J Malaysia. 2004 May;59 Suppl B:145-6.