PMID- 16013567 OWN - NLM STAT- MEDLINE DCOM- 20100602 LR - 20161018 IS - 1000-8713 (Print) IS - 1000-8713 (Linking) VI - 23 IP - 2 DP - 2005 Mar TI - [Study on characteristics of bias caused by flow injection-capillary electrophoresis with split-flow electrokinetic injection]. PG - 189-92 AB - The characteristics of bias caused by split-flow electrokinetic injection (SEKI), a new sample injection method applied in coupled flow injection-capillary electrophoretic system (FI-CE), was investigated using pseudoephedrine hydrochloride, a basic drug and ibuprofen, an acidic drug, as model analytes. It was found that bias imposed by SEKI under the conditions of continuous sample matrix/running buffer was similar to that did by electrokinetic injection (EKI). The linearity of calibration curve provided by SEKI was similar to that offered by non-bias hydrodynamic injection (HDI) but significantly better than that obtained by EKI. These features were exploited to improve analytical performances in simultaneous determination of the minor ingredient of pseudoephedrine hydrochloride and the major ingredient of ibuprofen in pharmaceutical preparation. Detectability of 0.7 mg/L for pseudoephedrine hydrochloride, was achieved at a sample throughput rate of 24 times per hour which is 30% lower than that obtained by HDI-based conventional CE. Eleven runs of a test solution containing 13.1 mg/L pseudoephedrine hydrochloride and 81.4 mg/L ibuprofen produced relative standard deviations (RSDs) of 2.8% for the minor ingredient and 1.2% for the major ingredient, which were improved in comparision to that obtained by HDI-based conventional CE. Analytical results for two batches of compound ibuprofen tablets by the SEKI-based FI-CE approach were in good agreement with that obtained by a conventional high performance liquid chromatographic method. FAU - Luo, Jinwen AU - Luo J AD - Zhejiang Institute for Drug Control, Hangzhou 310004, China. liwzhl@hzcnc.com FAU - Zhu, Hailin AU - Zhu H FAU - Li, Huilin AU - Li H LA - chi PT - English Abstract PT - Journal Article PT - Research Support, Non-U.S. Gov't PL - China TA - Se Pu JT - Se pu = Chinese journal of chromatography JID - 9424804 RN - 0 (Anti-Inflammatory Agents, Non-Steroidal) RN - 0 (Bronchodilator Agents) RN - 7CUC9DDI9F (Pseudoephedrine) RN - WK2XYI10QM (Ibuprofen) SB - IM MH - Anti-Inflammatory Agents, Non-Steroidal/*analysis/chemistry MH - Bronchodilator Agents/*analysis/chemistry MH - Electrophoresis, Capillary/*methods MH - Flow Injection Analysis/*methods MH - Ibuprofen/*analysis/chemistry MH - Pseudoephedrine/*analysis/chemistry EDAT- 2005/07/15 09:00 MHDA- 2010/06/03 06:00 CRDT- 2005/07/15 09:00 PHST- 2005/07/15 09:00 [pubmed] PHST- 2010/06/03 06:00 [medline] PHST- 2005/07/15 09:00 [entrez] PST - ppublish SO - Se Pu. 2005 Mar;23(2):189-92.