PMID- 16154523 OWN - NLM STAT- MEDLINE DCOM- 20051031 LR - 20191210 IS - 1570-0232 (Print) IS - 1570-0232 (Linking) VI - 825 IP - 1 DP - 2005 Oct 15 TI - Simultaneous enantioselective determination of amphetamine and congeners in hair specimens by negative chemical ionization gas chromatography-mass spectrometry. PG - 57-62 AB - Enantioselective quantification of amphetamine (AM), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethylamphetamine (MDEA) enantiomers in hair using gas chromatography-mass spectrometry (GC-MS) is described. Hair specimens were digested with 1M sodium hydroxide at 100 degrees C for 30 min and extracted by a solid phase procedure using Cleanscreen ZSDAU020. Extracted analytes were derivatised with (S)-heptafluorobutyrylprolyl chloride and the resulting diastereoisomers were quantified by GC-MS operating in the negative chemical ionization mode. Extraction yields were between 73.0 and 97.9%. Limits of detection varied in the range of 2.1-45.9 pg/mg hair, whereas the lowest limits of quantification varied between 4.3 and 91.8 pg/mg hair. Intra- and inter-assay precision and respective accuracy were acceptable. The enantiomeric ratios (R versus S) of AM, MA, MDA, MDMA and MDEA were determined in hair from suspected amphetamine abusers. Only MA and AM enantiomers were detectable in this collective and the quantification data showed in most cases higher concentrations of (R)-MA and (R)-AM than those of the corresponding (S)-enantiomers. FAU - Martins, Liliane AU - Martins L AD - National Laboratory of Health, Toxicology Division, University of Luxembourg, CRP-Sante, 162A, Avenue de la Faiencerie, Luxembourg L-1511, Luxembourg. martins@cu.lu FAU - Yegles, Michel AU - Yegles M FAU - Chung, Heesun AU - Chung H FAU - Wennig, Robert AU - Wennig R LA - eng PT - Journal Article PT - Validation Study DEP - 20050127 PL - Netherlands TA - J Chromatogr B Analyt Technol Biomed Life Sci JT - Journal of chromatography. B, Analytical technologies in the biomedical and life sciences JID - 101139554 RN - CK833KGX7E (Amphetamine) SB - IM MH - Amphetamine/*analysis MH - Calibration MH - Gas Chromatography-Mass Spectrometry/*methods MH - Hair/*chemistry MH - Reproducibility of Results MH - Sensitivity and Specificity MH - Stereoisomerism EDAT- 2005/09/13 09:00 MHDA- 2005/11/01 09:00 CRDT- 2005/09/13 09:00 PHST- 2004/10/16 00:00 [received] PHST- 2004/12/20 00:00 [revised] PHST- 2004/12/24 00:00 [accepted] PHST- 2005/09/13 09:00 [pubmed] PHST- 2005/11/01 09:00 [medline] PHST- 2005/09/13 09:00 [entrez] AID - S1570-0232(05)00037-1 [pii] AID - 10.1016/j.jchromb.2004.12.037 [doi] PST - ppublish SO - J Chromatogr B Analyt Technol Biomed Life Sci. 2005 Oct 15;825(1):57-62. doi: 10.1016/j.jchromb.2004.12.037. Epub 2005 Jan 27.