PMID- 16599145 OWN - NLM STAT- MEDLINE DCOM- 20070119 LR - 20181201 IS - 0250-3301 (Print) IS - 0250-3301 (Linking) VI - 27 IP - 1 DP - 2006 Jan TI - [Comparison of two types of double-lined simulated landfill leakage detection based on high voltage DC method]. PG - 181-3 AB - Two types of double high density polyethylene (HDPE) liners landfill that clay or geogrid was added between the two HDPE liners. The general resistance of the second mode is 15% larger than the general resistance of the first mode in the primary HDPE liner detection, and 20% larger than that of the first one in the secondary HDPE liner detection. High voltage DC method can accomplish the leakage detection and location of these two types of landfill and the error of leakage location is less than 10cm when electrode space is 1m. FAU - Yang, Ping AU - Yang P AD - School of Mechatronic Engineering, China University Mining and Technology (Beijing Campus), Beijing 100083, China. FAU - Nai, Chang-Xin AU - Nai CX FAU - Dong, Lu AU - Dong L FAU - Wang, Qi AU - Wang Q FAU - Wang, Yan-Wen AU - Wang YW LA - chi PT - Comparative Study PT - Journal Article PT - Research Support, Non-U.S. Gov't PL - China TA - Huan Jing Ke Xue JT - Huan jing ke xue= Huanjing kexue JID - 8405344 RN - 0 (Aluminum Silicates) RN - 0 (Soil Pollutants) RN - 9002-88-4 (Polyethylene) RN - T1FAD4SS2M (Clay) SB - IM MH - Aluminum Silicates MH - Clay MH - Electricity MH - Electrodes MH - Polyethylene/*analysis MH - Refuse Disposal/*methods MH - Soil Pollutants/*analysis EDAT- 2006/04/08 09:00 MHDA- 2007/01/20 09:00 CRDT- 2006/04/08 09:00 PHST- 2006/04/08 09:00 [pubmed] PHST- 2007/01/20 09:00 [medline] PHST- 2006/04/08 09:00 [entrez] PST - ppublish SO - Huan Jing Ke Xue. 2006 Jan;27(1):181-3.