PMID- 17319774 OWN - NLM STAT- MEDLINE DCOM- 20070426 LR - 20131121 IS - 0003-3219 (Print) IS - 0003-3219 (Linking) VI - 77 IP - 2 DP - 2007 Mar TI - Galvanic corrosion of metal injection molded (MIM) and conventional brackets with nickel-titanium and copper-nickel-titanium archwires. PG - 355-60 AB - OBJECTIVE: To compare the galvanic coupling of conventional and metal injection molded (MIM) brackets with commonly used orthodontic archwires. MATERIALS AND METHODS: Six of each type of bracket were suspended in lactic acid along with a sample of orthodontic wire (three nickel-titanium and three copper-nickel-titanium) for 28 days at 37 degrees C. The potential differences between the wires and brackets were recorded per second throughout the duration of the experiment. RESULTS: The MIM brackets exhibited potential differences similar to those seen for the conventional brackets. The greatest potential difference was found for MIM brackets with nickel-titanium wires (512 mV), whereas MIM brackets with copper-nickel-titanium wires had the smallest difference (115 mV). Scanning electron microscope (SEM)-energy-dispersive spectroscopic analysis of the tie-wing area of each bracket type indicated similar elemental composition in both brackets, but in slightly different percentages by weight. The MIM bracket exhibited extensive internal porosity, whereas the conventional bracket was more solid internally. CONCLUSION: The composition and manufacturing processes involved in fabricating MIM brackets impart corrosive properties similar to those seen in the bracket-wing area of conventional brackets and may provide a measurable benefit when taking into account the increased corrosion between the bracket and brazing alloy of conventional brackets. FAU - Siargos, Barbara AU - Siargos B AD - Department of Orthodontics, Marquette University, Wisconsin, USA. FAU - Bradley, Thomas G AU - Bradley TG FAU - Darabara, Myrsini AU - Darabara M FAU - Papadimitriou, George AU - Papadimitriou G FAU - Zinelis, Spiros AU - Zinelis S LA - eng PT - Comparative Study PT - Journal Article PL - United States TA - Angle Orthod JT - The Angle orthodontist JID - 0370550 RN - 0 (Copper NiTi) RN - 0 (Dental Alloys) RN - 12035-60-8 (titanium nickelide) RN - 789U1901C5 (Copper) RN - 7OV03QG267 (Nickel) RN - D1JT611TNE (Titanium) SB - IM MH - Copper/*chemistry MH - Corrosion MH - Dental Alloys/*chemistry MH - Electrogalvanism, Intraoral MH - Nickel/*chemistry MH - *Orthodontic Brackets MH - *Orthodontic Wires MH - Surface Properties MH - Titanium/*chemistry EDAT- 2007/02/27 09:00 MHDA- 2007/04/27 09:00 CRDT- 2007/02/27 09:00 PHST- 2006/02/01 00:00 [received] PHST- 2006/03/01 00:00 [accepted] PHST- 2007/02/27 09:00 [pubmed] PHST- 2007/04/27 09:00 [medline] PHST- 2007/02/27 09:00 [entrez] AID - 0003-3219-77-2-355 [pii] AID - 10.2319/0003-3219(2007)077[0355:GCOMIM]2.0.CO;2 [doi] PST - ppublish SO - Angle Orthod. 2007 Mar;77(2):355-60. doi: 10.2319/0003-3219(2007)077[0355:GCOMIM]2.0.CO;2.