PMID- 18425501 OWN - NLM STAT- MEDLINE DCOM- 20080811 LR - 20161124 IS - 1618-2650 (Electronic) IS - 1618-2642 (Linking) VI - 391 IP - 3 DP - 2008 Jun TI - Molecularly imprinted solid-phase extraction and flow-injection chemiluminescence for trace analysis of 2,4-dichlorophenol in water samples. PG - 1073-9 LID - 10.1007/s00216-008-2059-z [doi] AB - Highly sensitive flow-injection chemiluminescence (CL) combined with molecularly imprinted solid-phase extraction (MISPE) has been used for determination of 2,4-dichlorophenol (2,4-DCP) in water samples. The molecularly imprinted polymer (MIP) for 2,4-DCP was prepared by non-covalent molecular imprinting methods, using 4-vinylpyridine (4-VP) and ethylene glycol dimethacrylate (EGDMA) as the monomer and cross-linker, respectively. 2,4-DCP could be selectively adsorbed by the MIP and the adsorbed 2,4-DCP was determined by its enhancing effect on the weak chemiluminescence reaction between potassium permanganate and luminol. The enhanced CL intensity was linear in the range from 1 x 10(-7) to 2 x 10(-5) g mL(-1). The LOD (S/N = 3) was 1.8 x 10(-8) g mL(-1), and the relative standard deviation (RSD) was 3.0% (n = 11) for 1.4 x 10(-6) g mL(-1). The proposed method had been successfully applied to the determination of 2,4-DCP in river water. FAU - Feng, Qin-Zhong AU - Feng QZ AD - State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P. O. Box 2871, Beijing, 100085, China. FAU - Zhao, Li-Xia AU - Zhao LX FAU - Yan, Wei AU - Yan W FAU - Ji, Feng AU - Ji F FAU - Wei, Yan-Lin AU - Wei YL FAU - Lin, Jin-Ming AU - Lin JM LA - eng PT - Journal Article PT - Research Support, Non-U.S. Gov't DEP - 20080419 PL - Germany TA - Anal Bioanal Chem JT - Analytical and bioanalytical chemistry JID - 101134327 RN - 0 (Chlorophenols) RN - 0 (Cross-Linking Reagents) RN - 0 (Methacrylates) RN - 0 (Pyridines) RN - 0 (Water Pollutants, Chemical) RN - 7BK5G69305 (ethylene dimethacrylate) RN - I56G67XM8D (4-vinylpyridine) RN - R669TG1950 (2,4-dichlorophenol) SB - IM MH - Chlorophenols/*analysis MH - Cross-Linking Reagents/chemistry MH - Flow Injection Analysis/instrumentation/methods MH - Kinetics MH - *Luminescence MH - Methacrylates/chemistry MH - Molecular Imprinting/instrumentation/*methods MH - Pyridines/chemistry MH - Reproducibility of Results MH - Rivers/*chemistry MH - Sensitivity and Specificity MH - Solid Phase Extraction/instrumentation/*methods MH - Water Pollutants, Chemical/*analysis EDAT- 2008/04/22 09:00 MHDA- 2008/08/12 09:00 CRDT- 2008/04/22 09:00 PHST- 2007/11/19 00:00 [received] PHST- 2008/03/05 00:00 [accepted] PHST- 2008/02/23 00:00 [revised] PHST- 2008/04/22 09:00 [pubmed] PHST- 2008/08/12 09:00 [medline] PHST- 2008/04/22 09:00 [entrez] AID - 10.1007/s00216-008-2059-z [doi] PST - ppublish SO - Anal Bioanal Chem. 2008 Jun;391(3):1073-9. doi: 10.1007/s00216-008-2059-z. Epub 2008 Apr 19.