PMID- 18546200 OWN - NLM STAT- MEDLINE DCOM- 20090512 LR - 20200930 IS - 1552-4981 (Electronic) IS - 1552-4973 (Linking) VI - 88 IP - 1 DP - 2009 Jan TI - Evaluation of substrates for 90 degrees peel adhesion--a collaborative study. II. Transdermal drug delivery systems. PG - 61-5 LID - 10.1002/jbm.b.31149 [doi] AB - In a previous study on peel adhesion for medical tapes, it was shown that a stainless steel (SS) substrate better discriminated among medical tapes than a high-density polyethylene (HDPE) substrate. The objective of this study was to determine if a SS substrate would also better distinguish among transdermal drug delivery systems (TDDSs). Five TDDSs (Vivelle Dot, Climara, Catapres-TTS, Duragesic, and Mylan Fentanyl) were evaluated on three different substrates (SS, HDPE, and human cadaver skin). All measurements were made using a dwell time of approximately 3 min, a peel angle of 90 degrees, and a peel speed of 300 mm/min. Differences among TDDSs were greater for SS than for HDPE, using the F statistic for testing for differences among TDDSs means as a measure of heterogeneity, thereby indicating greater discrimination by SS. CI - (c) 2008 Wiley Periodicals, Inc. FAU - Wokovich, Anna M AU - Wokovich AM AD - Center for Drug Evaluation and Research, Food and Drug Administration, St. Louis, Missouri, USA. anna.wokovich@fda.hhs.gov FAU - Brown, Stanley A AU - Brown SA FAU - Shen, Meiyu AU - Shen M FAU - Doub, William H AU - Doub WH FAU - Cai, Bing AU - Cai B FAU - Sadrieh, Nakissa AU - Sadrieh N FAU - Chen, Mei Ling AU - Chen ML FAU - Machado, Stella AU - Machado S FAU - Buhse, Lucinda F AU - Buhse LF LA - eng PT - Journal Article PL - United States TA - J Biomed Mater Res B Appl Biomater JT - Journal of biomedical materials research. Part B, Applied biomaterials JID - 101234238 RN - 0 (Biocompatible Materials) RN - 4TI98Z838E (Estradiol) RN - 9002-88-4 (Polyethylene) RN - MN3L5RMN02 (Clonidine) RN - UF599785JZ (Fentanyl) SB - IM MH - Adhesiveness MH - *Administration, Cutaneous MH - Biocompatible Materials/*chemistry MH - Cadaver MH - Cell Adhesion MH - Clonidine/administration & dosage MH - *Drug Delivery Systems MH - Estradiol/administration & dosage MH - Fentanyl/administration & dosage MH - Humans MH - Materials Testing/*methods MH - Polyethylene/chemistry MH - Quality Control MH - Skin/*drug effects MH - *Surgical Tape EDAT- 2008/06/12 09:00 MHDA- 2009/05/13 09:00 CRDT- 2008/06/12 09:00 PHST- 2008/06/12 09:00 [pubmed] PHST- 2009/05/13 09:00 [medline] PHST- 2008/06/12 09:00 [entrez] AID - 10.1002/jbm.b.31149 [doi] PST - ppublish SO - J Biomed Mater Res B Appl Biomater. 2009 Jan;88(1):61-5. doi: 10.1002/jbm.b.31149.