PMID- 19159767 OWN - NLM STAT- MEDLINE DCOM- 20090227 LR - 20191210 IS - 1873-3573 (Electronic) IS - 0039-9140 (Linking) VI - 77 IP - 5 DP - 2009 Mar 15 TI - Separation/preconcentration of trace amounts of Cr, Cu and Pb in environmental samples by magnetic solid-phase extraction with Bismuthiol-II-immobilized magnetic nanoparticles and their determination by ICP-OES. PG - 1579-83 LID - 10.1016/j.talanta.2008.09.049 [doi] AB - A new method for separation/preconcentration of trace amounts of Cr, Cu and Pb in environmental samples by magnetic solid-phase extraction (SPE) with Bismuthiol-II-immobilized magnetic nanoparticles and their determination by ICP-OES has been developed. The separation of the target analytes from the aqueous solution containing the target analytes and Bismuthiol-II-immobilized magnetic nanoparticles was simply achieved by applying external magnetic field. Optimal experimental conditions including pH, sample volume, eluent concentration and volume and co-existing ions have been studied and established. Under the optimal experimental conditions, the detection limits for Cr, Cu and Pb with enrichment factors of 96, 95 and 87 were found to be 0.043, 0.058 and 0.085 ngmL(-1) and their relative standard deviations (R.S.D.s) were 3.5%, 4.6% and 3.7% (n=5, C=2 ngmL(-1)), respectively. The method was validated with certified reference material (GBW50009-88) of environmental water sample and the analytical results coincided well with the certified values. Furthermore, the method was successfully applied to the determination of target analytes in river and lake water samples. Compared with established methods, the proposed method is characterized with high enrichment factor, fast separation and low detection limits. FAU - Suleiman, Jibrin Sabo AU - Suleiman JS AD - Department of Chemistry, Wuhan University, Wuhan 430072, China. FAU - Hu, Bin AU - Hu B FAU - Peng, Hanyong AU - Peng H FAU - Huang, Chaozhang AU - Huang C LA - eng PT - Journal Article PT - Research Support, Non-U.S. Gov't PT - Validation Study DEP - 20081014 PL - Netherlands TA - Talanta JT - Talanta JID - 2984816R RN - 0 (Thiadiazoles) RN - 0 (Water Pollutants) RN - 0 (bismuthiol II) RN - 0R0008Q3JB (Chromium) RN - 2P299V784P (Lead) RN - 789U1901C5 (Copper) SB - IM MH - Chromium/*isolation & purification MH - Copper/*isolation & purification MH - Fresh Water MH - Lead/*isolation & purification MH - Magnetics MH - Metal Nanoparticles MH - Methods MH - Solid Phase Extraction/*methods MH - Thiadiazoles MH - Water Pollutants/isolation & purification MH - Water Purification/*methods EDAT- 2009/01/23 09:00 MHDA- 2009/02/28 09:00 CRDT- 2009/01/23 09:00 PHST- 2008/06/30 00:00 [received] PHST- 2008/09/24 00:00 [revised] PHST- 2008/09/26 00:00 [accepted] PHST- 2009/01/23 09:00 [entrez] PHST- 2009/01/23 09:00 [pubmed] PHST- 2009/02/28 09:00 [medline] AID - S0039-9140(08)00710-8 [pii] AID - 10.1016/j.talanta.2008.09.049 [doi] PST - ppublish SO - Talanta. 2009 Mar 15;77(5):1579-83. doi: 10.1016/j.talanta.2008.09.049. Epub 2008 Oct 14.