PMID- 20144414 OWN - NLM STAT- MEDLINE DCOM- 20100602 LR - 20221207 IS - 1932-2968 (Electronic) IS - 1932-2968 (Linking) VI - 3 IP - 5 DP - 2009 Sep 1 TI - Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: preliminary studies in Padova and Montpellier. PG - 1014-21 AB - New effort has been made to develop closed-loop glucose control, using subcutaneous (SC) glucose sensing and continuous subcutaneous insulin infusion (CSII) from a pump, and a control algorithm. An approach based on a model predictive control (MPC) algorithm has been utilized during closed-loop control in type 1 diabetes patients. Here we describe the preliminary clinical experience with this approach. Six type 1 diabetes patients (three in each of two clinical investigation centers in Padova and Montpellier), using CSII, aged 36 +/- 8 and 48 +/- 6 years, duration of diabetes 12 +/- 8 and 29 +/- 4 years, hemoglobin A1c 7.4% +/- 0.1% and 7.3% +/- 0.3%, body mass index 23.2 +/- 0.3 and 28.4 +/- 2.2 kg/m(2), respectively, were studied on two occasions during 22 h overnight hospital admissions 2-4 weeks apart. A Freestyle Navigator(R) continuous glucose monitor and an OmniPod insulin pump were applied in each trial. Admission 1 used open-loop control, while admission 2 employed closed-loop control using our MPC algorithm. In Padova, two out of three subjects showed better performance with the closed-loop system compared to open loop. Altogether, mean overnight plasma glucose (PG) levels were 134 versus 111 mg/dl during open loop versus closed loop, respectively. The percentage of time spent at PG > 140 mg/dl was 45% versus 12%, while postbreakfast mean PG was 165 versus 156 mg/dl during open loop versus closed loop, respectively. Also, in Montpellier, two patients out of three showed a better glucose control during closed-loop trials. Avoidance of nocturnal hypoglycemic excursions was a clear benefit during algorithm-guided insulin delivery in all cases. This preliminary set of studies demonstrates that closed-loop control based entirely on SC glucose sensing and insulin delivery is feasible and can be applied to improve glucose control in patients with type 1 diabetes, although the algorithm needs to be further improved to achieve better glycemic control. CI - 2009 Diabetes Technology Society. FAU - Bruttomesso, Daniela AU - Bruttomesso D AD - Department of Clinical and Experimental Medicine, Division of Metabolic Diseases, University of Padova, Padova, Italy. FAU - Farret, Anne AU - Farret A FAU - Costa, Silvana AU - Costa S FAU - Marescotti, Maria Cristina AU - Marescotti MC FAU - Vettore, Monica AU - Vettore M FAU - Avogaro, Angelo AU - Avogaro A FAU - Tiengo, Antonio AU - Tiengo A FAU - Dalla Man, Chiara AU - Dalla Man C FAU - Place, Jerome AU - Place J FAU - Facchinetti, Andrea AU - Facchinetti A FAU - Guerra, Stefania AU - Guerra S FAU - Magni, Lalo AU - Magni L FAU - De Nicolao, Giuseppe AU - De Nicolao G FAU - Cobelli, Claudio AU - Cobelli C FAU - Renard, Eric AU - Renard E FAU - Maran, Alberto AU - Maran A LA - eng PT - Comparative Study PT - Journal Article PT - Multicenter Study PT - Research Support, Non-U.S. Gov't DEP - 20090901 PL - United States TA - J Diabetes Sci Technol JT - Journal of diabetes science and technology JID - 101306166 RN - 0 (Blood Glucose) RN - 0 (Glycated Hemoglobin A) RN - 0 (Hypoglycemic Agents) RN - 0 (Insulin) RN - 0 (hemoglobin A1c protein, human) SB - IM MH - Adult MH - *Algorithms MH - Blood Glucose/*drug effects MH - *Blood Glucose Self-Monitoring/instrumentation MH - Diabetes Mellitus, Type 1/blood/diagnosis/*drug therapy MH - Diagnostic Equipment MH - Feasibility Studies MH - Female MH - France MH - Glycated Hemoglobin/metabolism MH - Humans MH - Hypoglycemia/chemically induced/prevention & control MH - Hypoglycemic Agents/*administration & dosage/adverse effects MH - Infusion Pumps, Implantable MH - Infusions, Subcutaneous MH - Insulin/*administration & dosage/adverse effects MH - *Insulin Infusion Systems MH - Italy MH - Male MH - Middle Aged MH - Models, Biological MH - *Pancreas, Artificial MH - Pilot Projects MH - Predictive Value of Tests MH - Time Factors PMC - PMC2769890 EDAT- 2010/02/11 06:00 MHDA- 2010/06/03 06:00 PMCR- 2010/09/01 CRDT- 2010/02/11 06:00 PHST- 2010/02/11 06:00 [entrez] PHST- 2010/02/11 06:00 [pubmed] PHST- 2010/06/03 06:00 [medline] PHST- 2010/09/01 00:00 [pmc-release] AID - dst.3.5.1014 [pii] AID - 10.1177/193229680900300504 [doi] PST - epublish SO - J Diabetes Sci Technol. 2009 Sep 1;3(5):1014-21. doi: 10.1177/193229680900300504.