PMID- 20678921 OWN - NLM STAT- MEDLINE DCOM- 20110207 LR - 20171116 IS - 1873-4235 (Electronic) IS - 0956-5663 (Linking) VI - 26 IP - 2 DP - 2010 Oct 15 TI - Molecularly imprinted polymeric microspheres for determination of bovine serum albumin based on flow injection chemiluminescence sensor. PG - 632-7 LID - 10.1016/j.bios.2010.07.009 [doi] AB - A novel flow injection chemiluminescence (FI-CL) sensor for the determination of bovine serum albumin (BSA) using molecularly imprinted polymeric microspheres (MIPMs) as recognition element is reported. The BSA-MIPM was synthesized by suspension polymerization in toluene, using methacrylic acid (MAA) as functional monomer and ethylene glycol dimethacrylate (EGDMA) as cross-linker in the bovine serum albumin template molecule. Scanning electron microscope (SEM) was employed to characterize the surface morphology of the resultant imprinted microspheres. Molecular modeling was employed to simulate the possible recognition process of the MIPM. Then the synthesized BSA-MIPM was employed as recognition element by packing into flow cell to establish a novel FI-CL sensor. The chemiluminescence (CL) intensity was correlated linear with the concentration of BSA over the range of 1.0x10(-8) to 5.0x10(-6) g mL(-1) and the detection limit was 1.5x10(-9) g mL(-1). The relative standard deviation (RSD) for the determination of 1.0x10(-7) g mL(-1) BSA was 1.4% (n=11). The sensor is reusable and has a great improvement in sensitivity and selectivity for CL analysis. As a result, the new MIPM-CL sensor had been successfully applied to the determination of BSA in milk samples. CI - Copyright (c) 2010 Elsevier B.V. All rights reserved. FAU - Yu, Jinghua AU - Yu J AD - Shandong Provincial Key Laboratory of Fluorine Chemistry and Chemical Materials, School of Chemistry and Chemical Engineering, University of Jinan, No. 106, Jiwei Road, Jinan 250022, China. FAU - Wan, Fuwei AU - Wan F FAU - Zhang, Congcong AU - Zhang C FAU - Yan, Mei AU - Yan M FAU - Zhang, Xiaona AU - Zhang X FAU - Wang, Shaowei AU - Wang S LA - eng PT - Journal Article PT - Research Support, Non-U.S. Gov't DEP - 20100713 PL - England TA - Biosens Bioelectron JT - Biosensors & bioelectronics JID - 9001289 RN - 0 (Polymers) RN - 27432CM55Q (Serum Albumin, Bovine) SB - IM MH - Biosensing Techniques/*instrumentation MH - Equipment Design MH - Equipment Failure Analysis MH - Flow Injection Analysis/*instrumentation MH - Luminescent Measurements/*instrumentation MH - Microspheres MH - Polymers/*chemistry MH - Serum Albumin, Bovine/*analysis MH - Surface Properties EDAT- 2010/08/04 06:00 MHDA- 2011/02/08 06:00 CRDT- 2010/08/04 06:00 PHST- 2010/02/08 00:00 [received] PHST- 2010/06/07 00:00 [revised] PHST- 2010/07/05 00:00 [accepted] PHST- 2010/08/04 06:00 [entrez] PHST- 2010/08/04 06:00 [pubmed] PHST- 2011/02/08 06:00 [medline] AID - S0956-5663(10)00384-2 [pii] AID - 10.1016/j.bios.2010.07.009 [doi] PST - ppublish SO - Biosens Bioelectron. 2010 Oct 15;26(2):632-7. doi: 10.1016/j.bios.2010.07.009. Epub 2010 Jul 13.