PMID- 20817436 OWN - NLM STAT- MEDLINE DCOM- 20111128 LR - 20110802 IS - 1873-4022 (Electronic) IS - 1873-4022 (Linking) VI - 36 IP - 3 DP - 2011 Autumn TI - Dosimetric comparison of manual and beam angle optimization of gantry angles in IMRT. PG - 313-6 LID - 10.1016/j.meddos.2010.07.001 [doi] AB - Dosimetric comparison of manual beam angle selection (MBS) and beam angle optimization (BAO) for IMRT plans is investigated retrospectively for 15 head and neck and prostate patients. The head and neck and prostate had planning target volumes (PTVs) ranging between 96.0 and 319.9 cm(3) and 153.6 and 321.3 cm(3), whereas OAR ranged between 8.3 and 47.8 cm(3) and 68.3 and 469.2 cm(3), respectively. In MBS, a standard coplanar 7-9 fields equally spaced gantry angles were used. In BAO, the selection of gantry angle was optimized by the algorithm for the same number of beams. The optimization and dose-volume constraints were kept the same for both techniques. Treatment planning was performed on the Eclipse treatment planning system. Our results showed that the dose-volume histogram for PTV are nearly identical in both techniques but BAO provided superior sparing of the organs at risk compared with the MBS. Also, MBS produced statistically significant higher monitor units (MU) and segments than the BAO; 13.1 +/- 6.6% (p = 0.012) and 10.4 +/- 13.6% (p = 0.140), and 14.6 +/- 5.6% (p = 1.003E-5) and 12.6 +/- 7.4% (p = 0.76E-3) for head and neck and prostate cases, respectively. The reduction in MU translates into the reduction in total body and integral dose. It is concluded that BAO provides advantage over MBS for most intenisty-modulated radiation therapy cases. CI - Copyright (c) 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved. FAU - Srivastava, Shiv P AU - Srivastava SP AD - Department of Radiation Oncology, Reid Hospital & Health Care Services, Richmond, IN 46202, USA. FAU - Das, Indra J AU - Das IJ FAU - Kumar, Arvind AU - Kumar A FAU - Johnstone, Peter A S AU - Johnstone PA LA - eng PT - Comparative Study PT - Journal Article DEP - 20100903 PL - United States TA - Med Dosim JT - Medical dosimetry : official journal of the American Association of Medical Dosimetrists JID - 8908862 SB - IM MH - Head and Neck Neoplasms/*radiotherapy MH - Humans MH - Male MH - Prostatic Neoplasms/*radiotherapy MH - Radiotherapy Dosage MH - Radiotherapy Planning, Computer-Assisted/*methods MH - Radiotherapy, Intensity-Modulated/*methods MH - Retrospective Studies EDAT- 2010/09/08 06:00 MHDA- 2011/12/13 00:00 CRDT- 2010/09/07 06:00 PHST- 2010/02/11 00:00 [received] PHST- 2010/06/30 00:00 [revised] PHST- 2010/07/11 00:00 [accepted] PHST- 2010/09/07 06:00 [entrez] PHST- 2010/09/08 06:00 [pubmed] PHST- 2011/12/13 00:00 [medline] AID - S0958-3947(10)00113-5 [pii] AID - 10.1016/j.meddos.2010.07.001 [doi] PST - ppublish SO - Med Dosim. 2011 Autumn;36(3):313-6. doi: 10.1016/j.meddos.2010.07.001. Epub 2010 Sep 3.