PMID- 21089176 OWN - NLM STAT- MEDLINE DCOM- 20110315 LR - 20211020 IS - 1098-2825 (Electronic) IS - 0887-8013 (Print) IS - 0887-8013 (Linking) VI - 24 IP - 6 DP - 2010 TI - Is specific gravity a good estimate of urine osmolality? PG - 426-30 LID - 10.1002/jcla.20424 [doi] AB - CONTEXT: Urine specific gravity (USG) is often used by clinicians to estimate urine osmolality. USG is measured either by refractometry or by reagent strip. OBJECTIVE: We studied the correlation of USG obtained by either method with a concurrently obtained osmolality. DESIGN: Using our laboratory's records, we retrospectively gathered data on 504 urine specimens on patients on whom a simultaneously drawn USG and an osmolality were available. Out of these, 253 USG's were measured by automated refractometry and 251 USG's were measured by reagent strip. Urinalysis data on these subjects were used to determine the correlation between USG and osmolality, adjusting for other variables that may impact the relationship. The other variables considered were pH, protein, glucose, ketones, nitrates, bilirubin, urobilinogen, hemoglobin, and leukocyte esterase. The relationships were analyzed by linear regression. RESULTS: This study demonstrated that USG obtained by both reagent strip and refractometry had a correlation of approximately 0.75 with urine osmolality. The variables affecting the correlation included pH, ketones, bilirubin, urobilinogen, glucose, and protein for the reagent strip and ketones, bilirubin, and hemoglobin for the refractometry method. At a pH of 7 and with an USG of 1.010 predicted osmolality is approximately 300 mosm/kg/H(2)O for either method. For an increase in SG of 0.010, predicted osmolality increases by 182 mosm/kg/H(2) O for the reagent strip and 203 mosm/kg/H(2)O for refractometry. Pathological urines had significantly poorer correlation between USG and osmolality than "clean" urines. CONCLUSION: In pathological urines, direct measurement of urine osmolality should be used. CI - (c) 2010 Wiley-Liss, Inc. FAU - Imran, Sethi AU - Imran S AD - Berkshire Medical Center, Internal Medicine, Pittsfield, Massachusetts, USA. imransethi79@yahoo.co.in FAU - Eva, Goldwater AU - Eva G FAU - Christopher, Shutty AU - Christopher S FAU - Flynn, Ethan AU - Flynn E FAU - Henner, David AU - Henner D LA - eng PT - Comparative Study PT - Journal Article PL - United States TA - J Clin Lab Anal JT - Journal of clinical laboratory analysis JID - 8801384 RN - 0 (Reagent Strips) SB - IM MH - Humans MH - Hydrogen-Ion Concentration MH - Linear Models MH - Osmolar Concentration MH - Reagent Strips MH - Refractometry MH - Retrospective Studies MH - Specific Gravity MH - Urinalysis/*methods MH - Urine/*chemistry PMC - PMC6647580 EDAT- 2010/11/23 06:00 MHDA- 2011/03/16 06:00 PMCR- 2010/11/18 CRDT- 2010/11/20 06:00 PHST- 2010/11/20 06:00 [entrez] PHST- 2010/11/23 06:00 [pubmed] PHST- 2011/03/16 06:00 [medline] PHST- 2010/11/18 00:00 [pmc-release] AID - JCLA20424 [pii] AID - 10.1002/jcla.20424 [doi] PST - ppublish SO - J Clin Lab Anal. 2010;24(6):426-30. doi: 10.1002/jcla.20424.