PMID- 21325993 OWN - NLM STAT- MEDLINE DCOM- 20110603 LR - 20220311 IS - 1534-6080 (Electronic) IS - 0041-1337 (Linking) VI - 91 IP - 8 DP - 2011 Apr 27 TI - No association of kidney graft loss with human leukocyte antigen antibodies detected exclusively by sensitive Luminex single-antigen testing: a Collaborative Transplant Study report. PG - 883-7 LID - 10.1097/TP.0b013e3182100f77 [doi] AB - BACKGROUND: It is unclear whether kidney transplant recipients with preformed donor-specific human leukocyte antigen (HLA) antibodies (DSA) detectable only in the highly sensitive Luminex single-antigen (LSA) assay are at an increased risk of graft failure. METHODS: We studied 3148 patients who received a deceased donor kidney graft between 1996 and 2008 and were enrolled in the prospective serum project of the Collaborative Transplant Study. There were 118 patients with graft loss during the first 3 years after transplantation on whom recipient and donor DNA was available for complete HLA typing. We compared the incidence of LSA-detected DSA in these patients with graft failure and matched controls with functioning grafts. All patients were found negative in the less-sensitive complement-dependent lymphocytotoxicity and enzyme-linked immunosorbent assays. RESULTS: When mean fluorescence intensity (MFI) of greater than or equal to 1000 was used as a cutoff for Luminex positivity, 118 patients with graft loss did not show a higher incidence of DSA against HLA-A, -B, -C, -DRB1/3/4/5, -DQA1, -DQB1, -DPA1, or -DPB1 antigens than 118 matched controls without graft loss (for all loci P not significant). The incidence of strong DSA (MFI >/=2000 or MFI >/=3000) detected only by LSA was low (for all loci between 0% and 5%) and did not identify unacceptable antigens that were relevant for graft loss within the first 3 years after transplantation. CONCLUSION: We conclude that, given currently practiced crossmatch procedures and immunosuppressive regimens, exclusion of donor organs carrying "unacceptable" HLA based exclusively on sensitive LSA antibody testing is not justified. CI - (c) 2011 by Lippincott Williams & Wilkins FAU - Susal, Caner AU - Susal C AD - Department of Transplantation Immunology, Institute of Immunology, University of Heidelberg, Heidelberg, Germany. caner.suesal@med.uni-heidelberg.de FAU - Ovens, Jorg AU - Ovens J FAU - Mahmoud, Khaled AU - Mahmoud K FAU - Dohler, Bernd AU - Dohler B FAU - Scherer, Sabine AU - Scherer S FAU - Ruhenstroth, Andrea AU - Ruhenstroth A FAU - Tran, Thuong Hien AU - Tran TH FAU - Heinold, Andreas AU - Heinold A FAU - Opelz, Gerhard AU - Opelz G LA - eng PT - Journal Article PL - United States TA - Transplantation JT - Transplantation JID - 0132144 RN - 0 (Antibodies) RN - 0 (HLA Antigens) RN - 0 (Immunosuppressive Agents) SB - IM CIN - Transplantation. 2011 Aug 27;92(4):e15; author reply e15-6. PMID: 21814123 MH - Antibodies/*blood MH - Case-Control Studies MH - *Enzyme-Linked Immunosorbent Assay MH - Female MH - Germany MH - Graft Rejection/blood/*immunology/prevention & control MH - *Graft Survival/drug effects MH - HLA Antigens/*immunology MH - Histocompatibility Testing MH - Humans MH - Immunosuppressive Agents/therapeutic use MH - Kidney Transplantation/*immunology MH - Male MH - Middle Aged MH - Predictive Value of Tests MH - Retrospective Studies MH - Sensitivity and Specificity MH - Treatment Outcome EDAT- 2011/02/18 06:00 MHDA- 2011/06/04 06:00 CRDT- 2011/02/18 06:00 PHST- 2011/02/18 06:00 [entrez] PHST- 2011/02/18 06:00 [pubmed] PHST- 2011/06/04 06:00 [medline] AID - 10.1097/TP.0b013e3182100f77 [doi] PST - ppublish SO - Transplantation. 2011 Apr 27;91(8):883-7. doi: 10.1097/TP.0b013e3182100f77.