PMID- 21448690 OWN - NLM STAT- MEDLINE DCOM- 20111018 LR - 20211020 IS - 1741-0444 (Electronic) IS - 0140-0118 (Linking) VI - 49 IP - 8 DP - 2011 Aug TI - Transesophageal left ventricular electrogram-recording and temporary pacing to improve patient selection for cardiac resynchronization. PG - 851-8 LID - 10.1007/s11517-011-0767-6 [doi] AB - Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients with inter- and intraventricular conduction delay. The aim of this pilot study was to test the feasibility of both transesophageal measurement of left ventricular (LV) electrical delay and transesophageal LV pacing prior to implantation, to better select patients for CRT. Esophageal TO8 Osypka catheter was perorally applied in 30 HF patients in position of maximum LV deflection to measure LV electrical delay and to study arterial pulse pressure (PP) during transesophageal bipolar LV pacing. There were 15 responders with a PP increase of a mean 65 +/- 24 mmHg to 79 +/- 27 mmHg (P < 0.001) and a mean LV electrical delay of 86.8 +/- 33 ms. The 15 non-responders with poor PP increase of a mean 63.5 +/- 23.5 mmHg to 64.1 +/- 23.9 mmHg (P = 0.065) had a significantly smaller LV electrical delay of 36 +/- 21 ms (P < 0.001). During a 34 +/- 26 month CRT follow-up, the responders New York Heart Association (NYHA) class improved from 3.1 +/- 0.35 to 2.1 +/- 0.35 (P < 0.001). Determination of left ventricular electrical delay by transesophageal electrogram recording and transesophageal left ventricular pacing may be additional useful techniques to improve patient selection for CRT. FAU - Heinke, Matthias AU - Heinke M AD - Division of Cardiology, Department of Internal Medicine I, Friedrich Schiller University of Jena, Erlanger Allee 101, 07740 Jena, Germany. matthias.heinke@med.uni-jena.de FAU - Ismer, Bruno AU - Ismer B FAU - Kuhnert, Helmut AU - Kuhnert H FAU - Figulla, Hans R AU - Figulla HR LA - eng PT - Journal Article DEP - 20110330 PL - United States TA - Med Biol Eng Comput JT - Medical & biological engineering & computing JID - 7704869 SB - IM MH - Adult MH - Aged MH - Blood Pressure/physiology MH - Cardiac Pacing, Artificial/*methods MH - Cardiac Resynchronization Therapy/methods MH - Electrocardiography/instrumentation/methods MH - Feasibility Studies MH - Female MH - Heart Failure/physiopathology/*therapy MH - Humans MH - Male MH - Middle Aged MH - Patient Selection MH - Pilot Projects EDAT- 2011/03/31 06:00 MHDA- 2011/10/19 06:00 CRDT- 2011/03/31 06:00 PHST- 2010/12/16 00:00 [received] PHST- 2011/03/14 00:00 [accepted] PHST- 2011/03/31 06:00 [entrez] PHST- 2011/03/31 06:00 [pubmed] PHST- 2011/10/19 06:00 [medline] AID - 10.1007/s11517-011-0767-6 [doi] PST - ppublish SO - Med Biol Eng Comput. 2011 Aug;49(8):851-8. doi: 10.1007/s11517-011-0767-6. Epub 2011 Mar 30.