PMID- 21530978 OWN - NLM STAT- MEDLINE DCOM- 20110829 LR - 20131121 IS - 1873-3778 (Electronic) IS - 0021-9673 (Linking) VI - 1218 IP - 23 DP - 2011 Jun 10 TI - Effective indirect enrichment and determination of nitrite ion in water and biological samples using ionic liquid-dispersive liquid-liquid microextraction combined with high-performance liquid chromatography. PG - 3595-600 LID - 10.1016/j.chroma.2011.04.014 [doi] AB - An ionic liquid dispersive liquid-liquid microextraction high-performance liquid chromatography (IL-DLLME-HPLC) method for effective enrichment and determination of nitrite ion in water and biological samples was developed. The method was based on the reaction of nitrite ion with p-nitroaniline in the presence of diphenylamine in acid media and IL-DLLME of azo product. The optimization of reaction and extraction conditions, such as kind and concentration of acid, reaction time, volume of reaction solvent, temperature, kind of extraction and dispersive solvent, volume of extraction and dispersive solvent, addition of salt, extraction and centrifugal time were studied. Under the optimal conditions, 1-octyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide IL-DLLME procedure provided high enrichment factor of 430 and good extraction recovery of 91.7% for nitrite ion. The linearity was observed in the range of 0.4-500.0 mug L(-)(1) with good correlation coefficient (r(2)=0.9996). The relative standard deviations (RSDs) for five replicate measurements varied between 1.5% and 4.8%. The limit of detection of the method (S/N=3) was 0.05 mug L(-)(1). The interference effect of some anions and cations was also tested. The developed method allowed achieving an excellent enrichment factor, yielding a lower LOD in comparison with other methods. Moreover, the proposed method was able to analyze nitrite ion in water and biological samples with satisfactory recovery ranged from 96.5% to 107.3%. CI - Copyright (c) 2011 Elsevier B.V. All rights reserved. FAU - He, Lijun AU - He L AD - School of Chemistry and Chemical Engineering, Henan University of Technology, Lianhua Street, Zhengzhou 450001, China. ljhe01@yahoo.com.cn FAU - Zhang, Kaige AU - Zhang K FAU - Wang, Caijuan AU - Wang C FAU - Luo, Xianli AU - Luo X FAU - Zhang, Shusheng AU - Zhang S LA - eng PT - Journal Article PT - Research Support, Non-U.S. Gov't DEP - 20110414 PL - Netherlands TA - J Chromatogr A JT - Journal of chromatography. A JID - 9318488 RN - 0 (Ionic Liquids) RN - 0 (Nitrites) RN - 0 (Water Pollutants, Chemical) RN - 059QF0KO0R (Water) RN - Y4S76JWI15 (Methanol) SB - IM MH - Adult MH - Chemical Fractionation/*methods MH - Chromatography, High Pressure Liquid/*methods MH - Female MH - Humans MH - Ionic Liquids/chemistry MH - Methanol MH - Nitrites/*analysis/isolation & purification MH - Reproducibility of Results MH - Rivers/chemistry MH - Saliva/*chemistry MH - Sensitivity and Specificity MH - Water/*chemistry MH - Water Pollutants, Chemical/analysis MH - Water Supply EDAT- 2011/05/03 06:00 MHDA- 2011/08/30 06:00 CRDT- 2011/05/03 06:00 PHST- 2010/12/30 00:00 [received] PHST- 2011/04/02 00:00 [revised] PHST- 2011/04/06 00:00 [accepted] PHST- 2011/05/03 06:00 [entrez] PHST- 2011/05/03 06:00 [pubmed] PHST- 2011/08/30 06:00 [medline] AID - S0021-9673(11)00482-1 [pii] AID - 10.1016/j.chroma.2011.04.014 [doi] PST - ppublish SO - J Chromatogr A. 2011 Jun 10;1218(23):3595-600. doi: 10.1016/j.chroma.2011.04.014. Epub 2011 Apr 14.