PMID- 21549440 OWN - NLM STAT- MEDLINE DCOM- 20111024 LR - 20161125 IS - 1879-0887 (Electronic) IS - 0167-8140 (Linking) VI - 99 IP - 2 DP - 2011 May TI - Comparison of the planning target volume based on three-dimensional CT and four-dimensional CT images of non-small-cell lung cancer. PG - 176-80 LID - 10.1016/j.radonc.2011.03.015 [doi] AB - BACKGROUND AND PURPOSE: To compare positional and volumetric differences of planning target volumes (PTVs) based on axial three-dimensional CT (3DCT) and four-dimensional CT (4DCT) for the primary tumor of non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: Twenty-eight patients with NSCLC underwent 3DCT and 4DCT scans of the thorax during normal free breathing. PTV(vector) was defined on 3DCT using the individual tumor motion vector measured by 4DCT accounting for tumor motion; PTV(4D) was defined on all phases of 4DCT images. In addition, a 7mm margin for microscopic disease and a 3mm setup margin were used for above PTVs, respectively. The differences in target position, volume and coverage between PTV(vector) and PTV(4D) were evaluated for tumors in different lobes, respectively. RESULTS: The median motion vector for tumors located in the upper lobe (group A) and in the middle lower lobe (group B) was 2.8 and 7mm, respectively. The mean centroid shifts between PTV(vector) and PTV(4D) in the LR, AP and CC directions for group A and B were close to zero. The median size ratio of PTV(4D) to PTV(vector) was 0.75 and 0.52 for group A and B. The motion vector showed a significant correlation to the ratio of PTV(4D) to PTV(vector) for group A and B (p=0.008 and 0.003). The median DI of PTV(vector) in PTV(4D) was 69.19% for group A and 51.60% for group B. The median DI of PTV(4D) in PTV(vector) was 98.99% for group A and 99.94% for group B. CONCLUSION: It is necessary to expand the internal margin isotropically in a single direction for 3DCT treatment planning due to the uncertainty of the 3DCT-based target position. The 3DCT-based PTV using individual margins provides a good coverage of the 4DCT-based PTV, meanwhile encompasses relatively large normal tissues, especially for middle and lower lobe tumors. We should be cautious about the use of the individual PTV derived from 3DCT in treatment planning. CI - Copyright (c) 2011 Elsevier Ireland Ltd. All rights reserved. FAU - Li, Feng Xiang AU - Li FX AD - Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Jinan, China. FAU - Li, Jian Bin AU - Li JB FAU - Zhang, Ying Jie AU - Zhang YJ FAU - Liu, Tong Hai AU - Liu TH FAU - Tian, Shi Yu AU - Tian SY FAU - Xu, Min AU - Xu M FAU - Shang, Dong Ping AU - Shang DP FAU - Ma, Chang Sheng AU - Ma CS LA - eng PT - Comparative Study PT - Journal Article DEP - 20110504 PL - Ireland TA - Radiother Oncol JT - Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology JID - 8407192 SB - IM MH - Adult MH - Aged MH - Aged, 80 and over MH - Carcinoma, Non-Small-Cell Lung/*diagnostic imaging MH - Female MH - *Four-Dimensional Computed Tomography MH - Humans MH - *Imaging, Three-Dimensional MH - Lung Neoplasms/*diagnostic imaging MH - Male MH - Middle Aged MH - Movement MH - Patient Positioning MH - Radiotherapy Planning, Computer-Assisted/*methods MH - Respiration MH - Statistics, Nonparametric MH - Tomography, X-Ray Computed/*methods EDAT- 2011/05/10 06:00 MHDA- 2011/10/25 06:00 CRDT- 2011/05/10 06:00 PHST- 2010/11/23 00:00 [received] PHST- 2011/03/08 00:00 [revised] PHST- 2011/03/27 00:00 [accepted] PHST- 2011/05/10 06:00 [entrez] PHST- 2011/05/10 06:00 [pubmed] PHST- 2011/10/25 06:00 [medline] AID - S0167-8140(11)00170-8 [pii] AID - 10.1016/j.radonc.2011.03.015 [doi] PST - ppublish SO - Radiother Oncol. 2011 May;99(2):176-80. doi: 10.1016/j.radonc.2011.03.015. Epub 2011 May 4.