PMID- 21756194 OWN - NLM STAT- MEDLINE DCOM- 20120606 LR - 20220912 IS - 1478-6427 (Electronic) IS - 1478-6419 (Linking) VI - 26 IP - 6 DP - 2012 TI - LC determination of luteolin-7-O-beta-D-glucoside and apigenin-7-O-beta-D-glucoside in rat plasma after administration of Humulus scandens extract and its application to pharmacokinetic studies. PG - 530-9 LID - 10.1080/14786419.2010.532127 [doi] AB - The present study was to investigate the pharmacokinetics of luteolin-7-O-beta-D-glucoside (LGL) and apigenin-7-O-beta-D-glucoside (AGL) in rat plasma after intravenous administration of the Humulus scandens extract (HSE). A simple and accurate high-performance liquid chromatographic (HPLC) method was successfully developed for simultaneous determination of LGL and AGL in rat plasma after the plasma protein was precipitated with methanol. HPLC analysis was performed on a C(1)(8) column with UV detection at 350 nm and a mobile phase of methanol-0.2% phosphoric acid (1 : 1, v/v). Calibration curves of LGL and AGL were linear over the concentration range of 0.16-20.0 and 0.06-7.20 microg mL(-)(1), respectively. The accuracy and precision of the two analytes at low, medium and high concentrations were within the range of -3.4% to 8.1%. The relative standard deviations (RSDs) of the intra- and inter-day precisions were less than 11.7% and 10.0%, respectively. The extraction recoveries (n = 5) varied from 91.9% to 104.1% for LGL and from 92.6% to 109.3% for AGL. The method was fully validated and successfully applied to a pharmacokinetic study of LGL and AGL in rat plasma after the intravenous administration of HSE. FAU - Chen, Zaixing AU - Chen Z AD - School of Pharmaceutical Sciences, China Medical University, 92 Beier Road, Shenyang, Liaoning Province 110001, People's Republic of China. FAU - Ying, Xixiang AU - Ying X FAU - Meng, Shu AU - Meng S FAU - Zhu, Xu AU - Zhu X FAU - Jiang, Hong AU - Jiang H FAU - Cao, Qishen AU - Cao Q FAU - Wang, Lin AU - Wang L FAU - Meng, Fanhao AU - Meng F LA - eng PT - Journal Article DEP - 20110715 PL - England TA - Nat Prod Res JT - Natural product research JID - 101167924 RN - 0 (Flavones) RN - 0 (Glucosides) RN - 0 (Plant Extracts) RN - 7OF2S66PCH (apigetrin) RN - 7V515PI7F6 (Apigenin) RN - 98J6XDS46I (luteolin-7-glucoside) SB - IM MH - Animals MH - Apigenin/*blood MH - Calibration MH - Chromatography, High Pressure Liquid MH - Flavones/*blood MH - Glucosides/*blood MH - Humulus/*chemistry MH - Injections, Intravenous MH - Plant Extracts/administration & dosage/*pharmacokinetics MH - Rats MH - Rats, Sprague-Dawley MH - Reproducibility of Results EDAT- 2011/07/16 06:00 MHDA- 2012/06/07 06:00 CRDT- 2011/07/16 06:00 PHST- 2011/07/16 06:00 [entrez] PHST- 2011/07/16 06:00 [pubmed] PHST- 2012/06/07 06:00 [medline] AID - 10.1080/14786419.2010.532127 [doi] PST - ppublish SO - Nat Prod Res. 2012;26(6):530-9. doi: 10.1080/14786419.2010.532127. Epub 2011 Jul 15.