PMID- 22063517 OWN - NLM STAT- MEDLINE DCOM- 20120816 LR - 20131121 IS - 1873-3573 (Electronic) IS - 0039-9140 (Linking) VI - 86 DP - 2011 Oct 30 TI - An anionic exchange stir rod sorptive extraction based on monolithic material for the extraction of non-steroidal anti-inflammatory drugs in environmental aqueous samples. PG - 103-8 LID - 10.1016/j.talanta.2011.08.020 [doi] AB - In this study, a stir rod sorptive extraction (SRSE) adsorbent material was prepared by coating poly(4-vinylpyridine-co-ethylene glycol dimethacrylate) [poly(VP-co-EDMA)] monolithic polymer on stir rod, and then applied to the extraction of three non-steroidal anti-inflammatory drugs (NSAIDs) in environmental aqueous samples. The preparation conditions of monolithic material such as the amount of porogen and the ratio of functional monomer to cross-linker were investigated. To achieve the best extraction efficiency, several parameters, including pH value of sample solution, salt concentration in sample matrix, desorption solvent, extraction time, and desorption time, were optimized. By combining SRSE and high performance liquid chromatography with ultraviolet detector, a SRSE-HPLC/UV method for the determination of NSAIDs in environmental aqueous samples was proposed successfully. The limits of detection (LODs) of the developed method for three NSAIDs ranged between 0.09 and 0.25 ng/mL. Good method reproducibility presented as intra- and inter-day precisions were also obtained with the relative standard deviations (RSDs) less than 8.7% and 9.8%, respectively. CI - Copyright A(c) 2011 Elsevier B.V. All rights reserved. FAU - Luo, Yan-Bo AU - Luo YB AD - Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, China. FAU - Zheng, Hao-Bo AU - Zheng HB FAU - Wang, Jian-Xing AU - Wang JX FAU - Gao, Qiang AU - Gao Q FAU - Yu, Qiong-Wei AU - Yu QW FAU - Feng, Yu-Qi AU - Feng YQ LA - eng PT - Journal Article PT - Research Support, Non-U.S. Gov't DEP - 20110831 PL - Netherlands TA - Talanta JT - Talanta JID - 2984816R RN - 0 (Anion Exchange Resins) RN - 0 (Anti-Inflammatory Agents, Non-Steroidal) RN - 0 (Water Pollutants, Chemical) RN - 059QF0KO0R (Water) SB - IM MH - Anion Exchange Resins/*analysis MH - Anti-Inflammatory Agents, Non-Steroidal/*analysis MH - Chromatography, High Pressure Liquid/methods MH - Environment MH - Solid Phase Extraction/*methods MH - Water/*analysis MH - Water Pollutants, Chemical/*analysis EDAT- 2011/11/09 06:00 MHDA- 2012/08/17 06:00 CRDT- 2011/11/09 06:00 PHST- 2011/05/09 00:00 [received] PHST- 2011/08/06 00:00 [revised] PHST- 2011/08/09 00:00 [accepted] PHST- 2011/11/09 06:00 [entrez] PHST- 2011/11/09 06:00 [pubmed] PHST- 2012/08/17 06:00 [medline] AID - S0039-9140(11)00720-X [pii] AID - 10.1016/j.talanta.2011.08.020 [doi] PST - ppublish SO - Talanta. 2011 Oct 30;86:103-8. doi: 10.1016/j.talanta.2011.08.020. Epub 2011 Aug 31.