PMID- 22245884 OWN - NLM STAT- MEDLINE DCOM- 20120618 LR - 20191210 IS - 1873-3557 (Electronic) IS - 1386-1425 (Linking) VI - 89 DP - 2012 Apr TI - Development of electrochemiluminescent inhibition method for determination of gentian violet in aquatic water. PG - 25-9 LID - 10.1016/j.saa.2011.12.012 [doi] AB - Gentian violet (GV) was found to quench the electrochemiluminescence (ECL) of the tris(2,2'-bipyridyl)ruthenium(II)/tris-n-propylamine (Ru(bpy)3(2+)-TPA) system at a glass carbon electrode (GCE). Based on the ECL signal changes, a simple and ultrasensitive detection method for GV in aquatic water was established. Under the optimized conditions, the quenched ECL intensity versus the logarithm of the concentration of GV was linear over a concentration range from 1.0x10(-10) to 5.0x10(-7) mol L(-1), and the limit of detection (LOD) was found to be 4.5x10(-12) mol L(-1) (S/N=3). The results obtained by the ECL system were better than other reported methods in literatures in terms of sensitivity or linear response range. The method was successfully applied to determine GV in aquatic water, and the relative standard deviations (RSDs) were found less than 6.3%, and the recoveries were obtained from 98.7 to 111.0%. Moreover, a possible mechanism of the quenching effect was primarily discussed based on UV-visible absorption spectra, cyclic voltammograms and IECL-E curves. CI - Copyright (c) 2011 Elsevier B.V. All rights reserved. FAU - Wang, Sui AU - Wang S AD - Faculty of Materials Science and Chemical Engineering, The State Key Laboratory Base of Novel Functional Materials and Preparation Science, Ningbo University, Ningbo 315211, China. chemwangsui@163.com FAU - Hao, Tingting AU - Hao T FAU - Yu, Xinwei AU - Yu X FAU - Gai, Panpan AU - Gai P FAU - Guo, Zhiyong AU - Guo Z LA - eng PT - Evaluation Study PT - Journal Article PT - Research Support, Non-U.S. Gov't DEP - 20111227 PL - England TA - Spectrochim Acta A Mol Biomol Spectrosc JT - Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy JID - 9602533 RN - 0 (Anti-Infective Agents, Local) RN - 0 (Water Pollutants, Chemical) RN - 059QF0KO0R (Water) RN - J4Z741D6O5 (Gentian Violet) SB - IM MH - Anti-Infective Agents, Local/*analysis MH - Electrochemical Techniques/methods MH - Gentian Violet/*analysis MH - Limit of Detection MH - Luminescent Measurements/*methods MH - Water/*analysis MH - Water Pollutants, Chemical/*analysis EDAT- 2012/01/17 06:00 MHDA- 2012/06/19 06:00 CRDT- 2012/01/17 06:00 PHST- 2011/03/14 00:00 [received] PHST- 2011/05/01 00:00 [revised] PHST- 2011/12/07 00:00 [accepted] PHST- 2012/01/17 06:00 [entrez] PHST- 2012/01/17 06:00 [pubmed] PHST- 2012/06/19 06:00 [medline] AID - S1386-1425(11)01086-9 [pii] AID - 10.1016/j.saa.2011.12.012 [doi] PST - ppublish SO - Spectrochim Acta A Mol Biomol Spectrosc. 2012 Apr;89:25-9. doi: 10.1016/j.saa.2011.12.012. Epub 2011 Dec 27.