PMID- 22500447 OWN - NLM STAT- MEDLINE DCOM- 20140702 LR - 20171116 IS - 1000-8713 (Print) IS - 1000-8713 (Linking) VI - 29 IP - 12 DP - 2011 Dec TI - [Determination of seven phenoxyacid herbicides in environmental water by high performance liquid chromatography coupled with three phase hollow fiber liquid phase microextraction]. PG - 1199-204 AB - A novel method for the simultaneous determination of seven phenoxyacid herbicides such as dicamba, fluroxypyr, 4-chlorophenoxyacetic acid (4-CPA), 2-methyl-4-chlorophenoxyacetic acid (MCPA), 2, 4-dichlorophenoxyacetic acid (2,4-D), 2,4-dichlorophenoxybutyric acid (2,4-DB) and 4-(2-methyl-4-chlorophenoxy) butyric acid (MCPB) in environmental water by three phase hollow fiber liquid phase microextraction (HF-LPME) coupled with high performance liquid chromatography (HPLC) was developed. In order to optimize the experimental conditions, the orthogonal test has been used. The effects of extraction solvent, pH of the donor phase and acceptor phase, extraction time, stirring speed and salt concentration on the detection were investigated. The optimal experimental conditions were as follows: octanol as organic solvent, pH 3 of donor phase, pH 12 of acceptor phase, extraction time of 30 min, stirring speed of 400 r/min. The results showed that the proposed method provided a wide linear range for 7 phenoxyacid herbicides with correlation coefficients of 0.995 3 - 0.998 8. The detection limits ranged from 0.2 to 1.0 microg/L. The enrichment factors were in the range of 76.7 - 121. The recoveries were in the range of 68% - 104% and the relative standard deviations (RSDs) were less than 8.1% for the environmental water samples. The method has the advantages of sensitivity, simplicity, fastness and the use of very small amounts of organic solvent. The method can meet the requirements of the determination of trace phenoxyacid herbicides in the environmental water samples, and the study provided a useful method for the analysis of trace substances in water samples. FAU - Peng, Xiaojun AU - Peng X AD - Xinhui Entry-Exit Inspection and Quarantine Bureau, Jiangmen 529100, China. peng2129@yahoo.com.cn FAU - Pang, Jinshan AU - Pang J FAU - Deng, Aihua AU - Deng A LA - chi PT - Journal Article PL - China TA - Se Pu JT - Se pu = Chinese journal of chromatography JID - 9424804 RN - 0 (Acetates) RN - 0 (Herbicides) RN - 0 (Phenols) RN - 0 (Pyridines) RN - 0 (Water Pollutants, Chemical) RN - 2577AQ9262 (2,4-Dichlorophenoxyacetic Acid) RN - 3229-70-7 (phenoxy radical) RN - 4EMM3U5P3K (4-chlorophenoxyacetic acid) RN - 8O40SHO197 (4,5-amino-3,5-dichloro-6-fluoro-2-pyridinyloxyacetic acid) RN - SJG3M6RY6H (Dicamba) SB - IM MH - 2,4-Dichlorophenoxyacetic Acid/*analogs & derivatives/analysis MH - Acetates/analysis MH - *Chromatography, High Pressure Liquid MH - Dicamba/analysis MH - Herbicides/*analysis MH - *Liquid Phase Microextraction MH - Phenols MH - Pyridines/analysis MH - Water Pollutants, Chemical/*analysis EDAT- 2012/04/17 06:00 MHDA- 2014/07/06 06:00 CRDT- 2012/04/17 06:00 PHST- 2012/04/17 06:00 [entrez] PHST- 2012/04/17 06:00 [pubmed] PHST- 2014/07/06 06:00 [medline] PST - ppublish SO - Se Pu. 2011 Dec;29(12):1199-204.