PMID- 23182792 OWN - NLM STAT- MEDLINE DCOM- 20131227 LR - 20130215 IS - 1879-0097 (Electronic) IS - 0109-5641 (Linking) VI - 29 IP - 3 DP - 2013 Mar TI - Non-destructive characterization of voids in six flowable composites using swept-source optical coherence tomography. PG - 278-86 LID - S0109-5641(12)00461-7 [pii] LID - 10.1016/j.dental.2012.11.004 [doi] AB - OBJECTIVE: The aim of this study was to evaluate the void frequency (V(F)) and void volume (V(V)) in different flowable composites using swept-source optical coherence tomography (SS-OCT). METHODS: Standard class I cavities were prepared and filled with six different flowable composites: Clearfil Majesty LV (MJ; Kuraray), MI Flow (MW; GC), MI Fil (ML; GC), Beautifil flow plus (BF; Shofu), Palfique Estelite low flow (EL; Tokuyama) and Surefil SDR flow (SF; Dentsply). The restorations were scanned under OCT. The OCT tomograms were analyzed and average V(F) and V(V) per restoration for each composite were calculated. Scanning electron microscope (SEM) was used to observe the structure of each composite. In addition, the flowability of the materials was evaluated measuring the displacement of each material placed up-right on a glass slide. V(F) and V(V) obtained by OCT were also compared to those calculated using micro-computed tomography (micro-CT). RESULTS: Kruskal-Wallis ANOVA and Mann-Whitney U tests revealed significantly different V(F) and V(V) values (p<0.05) among the composites. Voids ranging from 35 to 785 mum in diameter were detected in OCT tomograms. MJ showed highest V(F) and V(V) values followed by MW, but ML, BF, EL and SF showed no significant difference. Filler volume in composites showed a positive correlation with void formation, but flowability did not show a specific trend. Micro-CT evaluation validated the V(F) and V(V) calculation by OCT, with a significant correlation in void size (p<0.001, r=0.94). CONCLUSION: The results of this study indicate the reliability of SS-OCT for real-time void characterization of composite materials and restorations. Void formation in flowable composites is material dependent. CI - Copyright (c) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved. FAU - Nazari, Amir AU - Nazari A AD - Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan. FAU - Sadr, Alireza AU - Sadr A FAU - Saghiri, Mohammad Ali AU - Saghiri MA FAU - Campillo-Funollet, Marc AU - Campillo-Funollet M FAU - Hamba, Hidenori AU - Hamba H FAU - Shimada, Yasushi AU - Shimada Y FAU - Tagami, Junji AU - Tagami J FAU - Sumi, Yasunori AU - Sumi Y LA - eng PT - Journal Article PT - Research Support, Non-U.S. Gov't DEP - 20121124 PL - England TA - Dent Mater JT - Dental materials : official publication of the Academy of Dental Materials JID - 8508040 RN - 0 (Composite Resins) MH - Analysis of Variance MH - Animals MH - Cattle MH - Composite Resins/*chemistry MH - Dental Cavity Preparation MH - Dental Restoration, Permanent/*methods MH - Microscopy, Electron, Scanning MH - Reproducibility of Results MH - *Tomography, Optical Coherence/methods MH - X-Ray Microtomography/methods EDAT- 2012/11/28 06:00 MHDA- 2013/12/29 06:00 CRDT- 2012/11/28 06:00 PHST- 2012/03/19 00:00 [received] PHST- 2012/10/10 00:00 [revised] PHST- 2012/11/02 00:00 [accepted] PHST- 2012/11/28 06:00 [entrez] PHST- 2012/11/28 06:00 [pubmed] PHST- 2013/12/29 06:00 [medline] AID - S0109-5641(12)00461-7 [pii] AID - 10.1016/j.dental.2012.11.004 [doi] PST - ppublish SO - Dent Mater. 2013 Mar;29(3):278-86. doi: 10.1016/j.dental.2012.11.004. Epub 2012 Nov 24.