PMID- 23192160 OWN - NLM STAT- MEDLINE DCOM- 20130520 LR - 20151119 IS - 1536-0210 (Electronic) IS - 0020-9996 (Linking) VI - 48 IP - 1 DP - 2013 Jan TI - Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury. PG - 24-31 LID - 10.1097/RLI.0b013e3182718672 [doi] AB - OBJECTIVES: We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. BACKGROUND: Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. MATERIALS AND METHODS: A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (<30 days) troponin elevation greater than 2 times the upper limit of normal as the reference standard for acute myocardial injury. RESULTS: Of the 65 patients, there were 21 (32%) with acute myocardial injury. Image quality and artifact scores were significantly better with FSE-SPAIR compared with FSE-STIR (2.15 vs 2.68, P < 0.01; 2.62 vs 3.05, P < 0.01, respectively). The sensitivity, specificity, positive predictive value, and negative predictive value for acute myocardial injury were as follows: 29%, 93%, 67%, and 73% for FSE-SPAIR; 38%, 91%, 67%, and 75% for FSE-STIR; 71%, 98%, 94%, and 88% for clinical interpretation including LGE, T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence. CONCLUSIONS: Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance. FAU - Srichai, Monvadi B AU - Srichai MB AD - Department of Radiology, New York University School of Medicine, NY, USA. srichai@alum.mit.edu FAU - Lim, Ruth P AU - Lim RP FAU - Lath, Narayan AU - Lath N FAU - Babb, James AU - Babb J FAU - Axel, Leon AU - Axel L FAU - Kim, Daniel AU - Kim D LA - eng GR - K12HS019473/HS/AHRQ HHS/United States PT - Journal Article PT - Research Support, U.S. Gov't, P.H.S. PL - United States TA - Invest Radiol JT - Investigative radiology JID - 0045377 RN - 0 (Biomarkers) RN - 0 (Troponin) SB - IM MH - Artifacts MH - Biomarkers/blood MH - Blood MH - Female MH - Humans MH - *Magnetic Resonance Imaging/methods MH - Magnetic Resonance Imaging, Cine MH - Male MH - Middle Aged MH - Myocardial Infarction/*diagnosis MH - Predictive Value of Tests MH - Sensitivity and Specificity MH - Troponin/blood EDAT- 2012/11/30 06:00 MHDA- 2013/05/22 06:00 CRDT- 2012/11/30 06:00 PHST- 2012/11/30 06:00 [entrez] PHST- 2012/11/30 06:00 [pubmed] PHST- 2013/05/22 06:00 [medline] AID - 10.1097/RLI.0b013e3182718672 [doi] PST - ppublish SO - Invest Radiol. 2013 Jan;48(1):24-31. doi: 10.1097/RLI.0b013e3182718672.