PMID- 24200667 OWN - NLM STAT- MEDLINE DCOM- 20150623 LR - 20190608 IS - 2186-1005 (Electronic) IS - 1341-1098 (Linking) VI - 20 IP - 5 DP - 2014 TI - Adverse events of lung tissue stapling in thoracic surgery. PG - 370-7 AB - PURPOSE: The use of staplers for thoracic surgery has been regarded as a safe procedure though sometimes adverse events (AEs) of stapling are experienced. The aim of this study is to analyze AEs of lung tissue stapling. METHODS: A retrospective multi-institutional review was conducted by 27 institutions of the Central Japan Lung Cancer Surgery Study Group. During the research period, lung tissue stapling was performed 10908 times. RESULTS: Total number of AEs related to stapling was 81 (0.74%). Seventy events occurred intraoperatively and 11 events occurred postoperatively. Intraoperative stapling AEs were air leakage (n = 26), laceration of the adjacent lung tissue (n = 23), stapling failure (n = 14), oozing (n = 4), and others (n = 3). The postoperative AEs were prolonged air leakage (n = 9), bleeding from the chest wall (n = 1), and postoperative bleeding (n = 1). Only one case died of acute exacerbation of interstitial pneumonia which was induced after completion lobectomy to cure postoperative bleeding. No relationship was seen between the incidence of AE and cartridge colors or compression types of staplers except the length of cartridges. CONCLUSION: Lung tissue stapling in thoracic surgery was safe. The most frequent cause of AEs was stapler-tissue thickness mismatch. The appropriate selection of the cartridge color may decrease the AE incidence of the lung tissue stapling. FAU - Yano, Motoki AU - Yano M AD - Department of Oncology, Immunology and Surgery, Nagoya City University Graduate School of Medical Sciences, Nagoya, Aichi, Japan. FAU - Iwata, Hisashi AU - Iwata H FAU - Hashizume, Masahiro AU - Hashizume M FAU - Shigemitsu, Kikuo AU - Shigemitsu K FAU - Adachi, Katsutoshi AU - Adachi K FAU - Tokui, Toshiya AU - Tokui T FAU - Matsuyama, Takaaki AU - Matsuyama T LA - eng PT - Journal Article PT - Multicenter Study DEP - 20131108 PL - Japan TA - Ann Thorac Cardiovasc Surg JT - Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia JID - 9703158 SB - IM MH - Equipment Design MH - Humans MH - Japan MH - Lung/*surgery MH - Postoperative Complications/*etiology/mortality MH - Retrospective Studies MH - Risk Factors MH - Surgical Staplers MH - Surgical Stapling/*adverse effects/instrumentation/mortality MH - Thoracic Surgical Procedures/*adverse effects/instrumentation/mortality MH - Treatment Outcome EDAT- 2013/11/10 06:00 MHDA- 2015/06/24 06:00 CRDT- 2013/11/09 06:00 PHST- 2013/11/09 06:00 [entrez] PHST- 2013/11/10 06:00 [pubmed] PHST- 2015/06/24 06:00 [medline] AID - DN/JST.JSTAGE/atcs/oa.13-00161 [pii] AID - 10.5761/atcs.oa.13-00161 [doi] PST - ppublish SO - Ann Thorac Cardiovasc Surg. 2014;20(5):370-7. doi: 10.5761/atcs.oa.13-00161. Epub 2013 Nov 8.