PMID- 24432638 OWN - NLM STAT- MEDLINE DCOM- 20150708 LR - 20190923 IS - 1000-8713 (Print) IS - 1000-8713 (Linking) VI - 31 IP - 10 DP - 2013 Oct TI - [Screening and confirmation of carcinogenic dyes in textiles by high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry]. PG - 961-8 AB - A method of high performance liquid chromatography-linear ion trap/Orbitrap high resolution mass spectrometry (HPLC-LTQ/Orbitrap MS) was used to screen and confirm carcinogenic dyes in textiles. The analytes were extracted from textile samples with pyridine/water (1/1, v/v) in a water bath under controlled conditions (95 degrees C, 150 r/min), and then filtered with a 0.22 microm polytetrafluoroetylene (PTFE) membrane. The eluates were separated on a CAPCELL PAK C18 column (100 mm x 2.0 mm, 5 microm) using gradient elution with acetonitrile/ 5 mmol/L ammonium acetate aqueous solution containing 0.01% formic acid (in positive mode) and acetonitrile/5 mmol/L ammonium acetate aqueous solution (in negative mode), and finally detected by HPLC-LTQ/Orbitrap MS in ESI modes. Full scan experiments were performed over the range of m/z 200-800. The screening and quantitative analysis were carried out by the accurate mass of quasi-molecular ion and the peak area in extracted chromatogram with accurate mass, respectively. The confirmatory analysis for target compounds was performed with the retention time and qualitative fragments obtained by data-dependent scan mode. Under the optimal conditions, nine carcinogenic dyes were routinely detected with mass accuracy below 5 x 10(-6) (5 ppm), and good linearities were provided in their respective linear ranges with correlation coefficients higher than 0.99. The limits of detection were in the range of 0.125-25 mg/kg. The average recoveries at three spiked levels were in the range of 62.13%116.28% with the relative standard deviations (RSDs) lower than 15%. The proposed method was applied to screen and confirm the nine carcinogenic dyes in textile samples. It is convenient and reliable. FAU - Xiu, Xiaoli AU - Xiu X AD - College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao 266042, China. FAU - Luo, Xin AU - Luo X AD - Technical Center for Inspection and Quarantine of Shandong Entry-Exit Inspection and Quarantine Bureau, Qingdao 266002, China. FAU - Niu, Zengyuan AU - Niu Z AD - Technical Center for Inspection and Quarantine of Shandong Entry-Exit Inspection and Quarantine Bureau, Qingdao 266002, China. FAU - Ye, Xiwen AU - Ye X AD - Technical Center for Inspection and Quarantine of Shandong Entry-Exit Inspection and Quarantine Bureau, Qingdao 266002, China. FAU - Zhixu, Tang AU - Zhixu T AD - Technical Center for Inspection and Quarantine of Shandong Entry-Exit Inspection and Quarantine Bureau, Qingdao 266002, China. FAU - Li, Jingying AU - Li J AD - College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao 266042, China. FAU - Wang, Yongwei AU - Wang Y AD - Thermo Fisher Scientific (China), Beijing 100007, China. FAU - Du, Wei AU - Du W AD - Thermo Fisher Scientific (China), Beijing 100007, China. LA - chi PT - Journal Article PL - China TA - Se Pu JT - Se pu = Chinese journal of chromatography JID - 9424804 RN - 0 (Carcinogens) RN - 0 (Coloring Agents) SB - IM MH - Carcinogens/*analysis MH - Chromatography, Liquid MH - Coloring Agents/*analysis MH - Mass Spectrometry MH - *Textiles EDAT- 2014/01/18 06:00 MHDA- 2015/07/15 06:00 CRDT- 2014/01/18 06:00 PHST- 2014/01/18 06:00 [entrez] PHST- 2014/01/18 06:00 [pubmed] PHST- 2015/07/15 06:00 [medline] AID - 10.3724/sp.j.1123.2013.04037 [doi] PST - ppublish SO - Se Pu. 2013 Oct;31(10):961-8. doi: 10.3724/sp.j.1123.2013.04037.