PMID- 25395292 OWN - NLM STAT- MEDLINE DCOM- 20150910 LR - 20181202 IS - 2211-0690 (Electronic) IS - 2211-0682 (Linking) VI - 20 IP - 1 DP - 2015 Feb TI - Reagent and labor cost optimization through automation of fluorescence in situ hybridization (FISH) with the VP 2000: an Italian case study. PG - 25-31 LID - 10.1177/2211068214558294 [doi] AB - In the modern molecular diagnostic laboratory, cost considerations are of paramount importance. Automation of complex molecular assays not only allows a laboratory to accommodate higher test volumes and throughput but also has a considerable impact on the cost of testing from the perspective of reagent costs, as well as hands-on time for skilled laboratory personnel. The following study tracked the cost of labor (hands-on time) and reagents for fluorescence in situ hybridization (FISH) testing in a routine, high-volume pathology and cytogenetics laboratory in Treviso, Italy, over a 2-y period (2011-2013). The laboratory automated FISH testing with the VP 2000 Processor, a deparaffinization, pretreatment, and special staining instrument produced by Abbott Molecular, and compared hands-on time and reagent costs to manual FISH testing. The results indicated significant cost and time saving when automating FISH with VP 2000 when more than six FISH tests were run per week. At 12 FISH assays per week, an approximate total cost reduction of 55% was observed. When running 46 FISH specimens per week, the cost saving increased to 89% versus manual testing. The results demonstrate that the VP 2000 processor can significantly reduce the cost of FISH testing in diagnostic laboratories. CI - (c) 2014 Society for Laboratory Automation and Screening. FAU - Zanatta, Lucia AU - Zanatta L AD - Department of Oncology and Pathology, General Hospital of Treviso, Treviso, Italy luzanatta@ulss.tv.it. FAU - Valori, Laura AU - Valori L AD - Department of Oncology and Pathology, General Hospital of Treviso, Treviso, Italy. FAU - Cappelletto, Eleonora AU - Cappelletto E AD - Department of Oncology and Pathology, General Hospital of Treviso, Treviso, Italy. FAU - Pozzebon, Maria Elena AU - Pozzebon ME AD - Department of Oncology and Pathology, General Hospital of Treviso, Treviso, Italy. FAU - Pavan, Elisabetta AU - Pavan E AD - Department of Oncology and Pathology, General Hospital of Treviso, Treviso, Italy. FAU - Dei Tos, Angelo Paolo AU - Dei Tos AP AD - Department of Oncology and Pathology, General Hospital of Treviso, Treviso, Italy. FAU - Merkle, Dennis AU - Merkle D AD - Abbott Molecular, Max-Planck-Ring 2, Wiesbaden, Germany. LA - eng PT - Journal Article DEP - 20141113 PL - United States TA - J Lab Autom JT - Journal of laboratory automation JID - 101558509 RN - 0 (Indicators and Reagents) SB - IM EIN - J Lab Autom. 2016 Feb;21(1):222. PMID: 26792900 MH - Automation, Laboratory/*economics/*methods MH - Cytogenetics/economics/methods MH - Health Workforce/*economics MH - Humans MH - In Situ Hybridization, Fluorescence/*economics/*methods MH - Indicators and Reagents/*economics MH - Italy MH - Pathology/economics/methods MH - Time Factors OTO - NOTNLM OT - FISH OT - VP 2000 OT - automation OT - cost reduction OT - fluorescence in situ hybridization EDAT- 2014/11/15 06:00 MHDA- 2015/09/12 06:00 CRDT- 2014/11/15 06:00 PHST- 2014/11/15 06:00 [entrez] PHST- 2014/11/15 06:00 [pubmed] PHST- 2015/09/12 06:00 [medline] AID - 2211068214558294 [pii] AID - 10.1177/2211068214558294 [doi] PST - ppublish SO - J Lab Autom. 2015 Feb;20(1):25-31. doi: 10.1177/2211068214558294. Epub 2014 Nov 13.