PMID- 25562743 OWN - NLM STAT- MEDLINE DCOM- 20151125 LR - 20181202 IS - 1873-4235 (Electronic) IS - 0956-5663 (Linking) VI - 68 DP - 2015 Jun 15 TI - Simultaneous quantitative detection of multiple tumor markers with a rapid and sensitive multicolor quantum dots based immunochromatographic test strip. PG - 156-162 LID - S0956-5663(14)01005-7 [pii] LID - 10.1016/j.bios.2014.12.051 [doi] AB - A novel multicolor quantum dots (QDs) based immunochromatographic test strip (ICTS) was developed for simultaneous quantitative detection of multiple tumor markers, by utilizing alpha fetoprotein (AFP) and carcinoembryonic antigen (CEA) as models. The immunosensor could realize simultaneous quantitative detection of tumor markers with only one test line and one control line on the nitrocellulose membrane (NC membrane) due to the introduction of multicolor QDs. In this method, a mixture of mouse anti-AFP McAb and mouse anti-CEA McAb was coated on NC membrane as test line and goat anti-mouse IgG antibody was coated as control line. Anti-AFP McAb-QDs546 conjugates and anti-CEA McAb-QDs620 conjugates were mixed and applied to the conjugate pad. Simultaneous quantitative detection of multiple tumor markers was achieved by detecting the fluorescence intensity of captured QDs labels on test line and control line using a test strip reader. Under the optimum conditions, AFP and CEA could be detected as low as 3 ng/mL and 2 ng/mL in 15 min with a sample volume of 80 muL, and no obvious cross-reactivity was observed. The immunosensor was validated with 130 clinical samples and in which it exhibited high sensitivity (93% for AFP and 87% for CEA) and specificity (94% for AFP and 97% for CEA). The immunosensor also demonstrated high recoveries (87.5-113% for AFP and 90-97.3% for CEA) and low relative standard deviations (RSDs) (2.8-6.2% for AFP and 4.9-9.6% for CEA) when testing spiked human serum. This novel multicolor QDs based ICTS provides an easy and rapid, simultaneous quantitative detecting strategy for point-of-care testing of tumor markers. CI - Copyright (c) 2014 Elsevier B.V. All rights reserved. FAU - Wang, Chunying AU - Wang C AD - Schlool of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu 610054, China. FAU - Hou, Fei AU - Hou F AD - Schlool of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu 610054, China. FAU - Ma, Yicai AU - Ma Y AD - Schlool of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu 610054, China. Electronic address: yicaima@sina.com. LA - eng PT - Journal Article PT - Research Support, Non-U.S. Gov't DEP - 20141223 PL - England TA - Biosens Bioelectron JT - Biosensors & bioelectronics JID - 9001289 RN - 0 (Antibodies) RN - 0 (Biomarkers, Tumor) RN - 0 (Carcinoembryonic Antigen) RN - 0 (alpha-Fetoproteins) SB - IM MH - Animals MH - Antibodies/chemistry MH - Biomarkers, Tumor/chemistry/*isolation & purification MH - *Biosensing Techniques MH - Carcinoembryonic Antigen/chemistry/*isolation & purification MH - Chromatography, Affinity MH - Humans MH - Mice MH - Neoplasms/*diagnosis MH - Quantum Dots/chemistry MH - alpha-Fetoproteins/chemistry/*isolation & purification OTO - NOTNLM OT - Immunochromatographic test strip OT - Multicolor quantum dots OT - Multiple tumor markers OT - One test line OT - Simultaneous quantitative detection EDAT- 2015/01/07 06:00 MHDA- 2015/12/15 06:00 CRDT- 2015/01/07 06:00 PHST- 2014/09/27 00:00 [received] PHST- 2014/12/09 00:00 [revised] PHST- 2014/12/22 00:00 [accepted] PHST- 2015/01/07 06:00 [entrez] PHST- 2015/01/07 06:00 [pubmed] PHST- 2015/12/15 06:00 [medline] AID - S0956-5663(14)01005-7 [pii] AID - 10.1016/j.bios.2014.12.051 [doi] PST - ppublish SO - Biosens Bioelectron. 2015 Jun 15;68:156-162. doi: 10.1016/j.bios.2014.12.051. Epub 2014 Dec 23.