PMID- 25771541 OWN - NLM STAT- MEDLINE DCOM- 20150901 LR - 20190923 IS - 1000-8713 (Print) IS - 1000-8713 (Linking) VI - 32 IP - 11 DP - 2014 Nov TI - [Enantioseparation and determination of atenolol enantiomers in tables on a beta-cyclodextrin-based chiral stationary phase by high performance liquid chromatography]. PG - 1219-24 AB - A novel dinitrophenyl ether beta-cyclodextrin-bonded chiral stationary phase (NESP) for HPLC was prepared with ordered mesoporous SBA-15 as matrix. The fast enantioseparation of atenolol enantiomers on the new stationary phase was achieved through the optimization of mobile phase composition, column temperature and other factors in polar organic solvent mode. The optimized composition of mobile phase was acetonitrile/methanol/glacial acetic acid/triethylamine (90:10:2.5:3.0, v/v/v/v) at the flow rate of 0.5 mL/min. The column tem- perature was set at 20 degrees C. The detection wavelength was 275 nm. The resolution of atenolol enantiomers was 1.73 with a rather short analysis time, about 20 min, under the above conditions. The atenolol was extracted with methanol from the tablets and analyzed by direct injection for HPLC. A new quantitative method of atenolol enantiomers in tablets was established after the condition optimization. The good linear relationships for two atenolol enantiomers were observed in the range of 2.5-100 mg/L with r of 0. 999 2 and 0. 998 9, respectively. The recoveries of atenolol enantiomers in tablet samples were 94.60%-97.24%. The relative standard deviations (RSDs) of this method were not greater than 0.92% for intra-day and 1.86% for inter-day, respectively. The detection limits (S/N = 3) of concentrations were less than 0.2 mg/L for both enantiomers. The established method is simple and of high selectivity, high recovery and low cost for enantiomer analysis by using homemade cyclodextrin-based chiral column. It has a good application prospect for the fast quality control and the pharmacokinetics study of chiral drugs. FAU - Cheng, Biaoping AU - Cheng B FAU - Li, Laisheng AU - Li L FAU - Zhou, Rendan AU - Zhou R FAU - Nie, Guizhen AU - Nie G FAU - Zhang, Hongfu AU - Zhang H LA - chi PT - Journal Article PL - China TA - Se Pu JT - Se pu = Chinese journal of chromatography JID - 9424804 RN - 0 (Tablets) RN - 0 (beta-Cyclodextrins) RN - 50VV3VW0TI (Atenolol) SB - IM MH - Atenolol/*analysis MH - Chromatography, High Pressure Liquid MH - Stereoisomerism MH - Tablets MH - beta-Cyclodextrins EDAT- 2015/03/17 06:00 MHDA- 2015/09/02 06:00 CRDT- 2015/03/17 06:00 PHST- 2015/03/17 06:00 [entrez] PHST- 2015/03/17 06:00 [pubmed] PHST- 2015/09/02 06:00 [medline] AID - 10.3724/sp.j.1123.2014.07018 [doi] PST - ppublish SO - Se Pu. 2014 Nov;32(11):1219-24. doi: 10.3724/sp.j.1123.2014.07018.