PMID- 27163321 OWN - NLM STAT- MEDLINE DCOM- 20170523 LR - 20170523 IS - 1878-7401 (Electronic) IS - 0928-7329 (Linking) VI - 24 Suppl 2 DP - 2016 Apr 29 TI - Echocardiographic evaluation of mechanical dyssynchrony in heart failure patients with reduced ejection fraction. PG - S587-92 LID - 10.3233/THC-161185 [doi] AB - The aim of this study is to observe the differences between mechanical and electrical dyssynchrony in patients with impaired systolic ventricular function and symptomatic heart failure and to highlight the importance of mechanical dyssynchrony besides electrical dyssynchrony in clinical guidelines and clinical practice. Fifty-eight patients with heart failure, who are with the New York Heart Association (NYHA) functional class II-IV and left ventricular ejection fraction (LVEF) under 35%, were enrolled. Patients were divided into two groups, according to the duration of QRS complex (> 120 ms and