PMID- 27331587 OWN - NLM STAT- MEDLINE DCOM- 20170523 LR - 20200930 IS - 1944-7884 (Electronic) IS - 1525-4135 (Print) IS - 1525-4135 (Linking) VI - 72 Suppl 1 IP - Suppl 1 DP - 2016 Jun 1 TI - Randomized Controlled Trial of the ShangRing for Adult Medical Male Circumcision: Safety, Effectiveness, and Acceptability of Using 7 Versus 14 Device Sizes. PG - S30-5 LID - 10.1097/QAI.0000000000001015 [doi] AB - OBJECTIVES: To assess the safety, effectiveness, and acceptability of providing a reduced number of ShangRing sizes for adult voluntary medical male circumcision (VMMC) within routine service delivery in Lusaka, Zambia. METHODS: We conducted a randomized controlled trial and enrolled 500 HIV-negative men aged 18-49 years at 3 clinics. Participants were randomized to 1 of 2 study arms (Standard Sizing arm vs Modified Sizing arm) in a 1:1 ratio. All 14 adult ShangRing sizes (40-26 mm inner diameter, each varying by 1 mm) were available in the Standard Sizing arm; the Modified Sizing arm used every other size (40, 38, 36, 34, 32, 30, 28 mm inner diameter). Each participant was scheduled for 2 follow-up visits: the removal visit (day 7 after placement) and the healing check visit (day 42 after placement), when they were evaluated for adverse events (AEs), pain, and healing. RESULTS: Four hundred and ninety-six men comprised the analysis population, with 255 in the Standard Sizing arm and 241 in the Modified Sizing arm. Three men experienced a moderate or severe AEs (0.6%), including 2 in the Standard Sizing arm (0.8%) and 1 in the Modified Sizing arm (0.4%). 73.2% of participants were completely healed at the scheduled day 42 healing check visit, with similar percentages across study arms. Virtually all (99.6%) men, regardless of study arm, stated that they were very satisfied or satisfied with the appearance of their circumcised penis, and 98.6% stated that they would recommend ShangRing circumcision to family/friends. CONCLUSIONS: The moderate/severe AE rate was low and similar in the 2 study arms, suggesting that provision of one-half the number of adult device sizes is sufficient for safe service delivery. Effectiveness, time to healing, and acceptability were similar in the study arms. The simplicity of the ShangRing technique, and its relative speed, could facilitate VMMC program goals. In addition, sufficiency of fewer device sizes would simplify logistics and inventory. FAU - Feldblum, Paul J AU - Feldblum PJ AD - *Global Health Department, FHI 360, Durham, NC; daggerDepartment of Surgery, University Teaching Hospital, Lusaka, Zambia; double daggerFHI 360, Lusaka, Zambia; and section signFHI 360, Nairobi, Kenya. FAU - Zulu, Robert AU - Zulu R FAU - Linyama, David AU - Linyama D FAU - Long, Sarah AU - Long S FAU - Nonde, Thikazi Jere AU - Nonde TJ FAU - Lai, Jaim Jou AU - Lai JJ FAU - Kashitala, Joshua AU - Kashitala J FAU - Veena, Valentine AU - Veena V FAU - Kasonde, Prisca AU - Kasonde P LA - eng PT - Journal Article PT - Randomized Controlled Trial PL - United States TA - J Acquir Immune Defic Syndr JT - Journal of acquired immune deficiency syndromes (1999) JID - 100892005 SB - IM MH - Adolescent MH - Adult MH - Circumcision, Male/adverse effects/*instrumentation MH - Humans MH - Male MH - Middle Aged MH - Young Adult PMC - PMC4936423 COIS- The authors have no conflicts of interest to disclose. EDAT- 2016/06/23 06:00 MHDA- 2017/05/24 06:00 PMCR- 2016/07/07 CRDT- 2016/06/23 06:00 PHST- 2016/06/23 06:00 [entrez] PHST- 2016/06/23 06:00 [pubmed] PHST- 2017/05/24 06:00 [medline] PHST- 2016/07/07 00:00 [pmc-release] AID - 00126334-201606011-00006 [pii] AID - QAIV16735 [pii] AID - 10.1097/QAI.0000000000001015 [doi] PST - ppublish SO - J Acquir Immune Defic Syndr. 2016 Jun 1;72 Suppl 1(Suppl 1):S30-5. doi: 10.1097/QAI.0000000000001015.