PMID- 27873521 OWN - NLM STAT- MEDLINE DCOM- 20170217 LR - 20181202 IS - 1976-2437 (Electronic) IS - 0513-5796 (Print) IS - 0513-5796 (Linking) VI - 58 IP - 1 DP - 2017 Jan TI - A Case of Recurrent Urticaria Due to Formaldehyde Release from Root-Canal Disinfectant. PG - 252-254 LID - 10.3349/ymj.2017.58.1.252 [doi] AB - Although formaldehyde is well known to cause type 4 hypersensitivity, immunoglobulin E (IgE)-mediated hypersensitivity to formaldehyde is rare. Here, we report a case of recurrent generalized urticaria after endodontic treatment using a para-formaldehyde (PFA)-containing root canal sealant and present a review of previous studies describing cases of immediate hypersensitivity reactions to formaldehyde. A 50-year-old man visited our allergy clinic for recurrent generalized urticaria several hours after endodontic treatment. Prick tests to latex, lidocaine, and formaldehyde showed negative reactions. However, swelling and redness at the prick site continued for several days. The level of formaldehyde-specific IgE was high (class 4). Thus, the patient was deemed to have experienced an IgE-mediated hypersensitivity reaction caused by the PFA used in the root canal disinfectant. Accordingly, we suggest that physicians should pay attention to type I hypersensitivity reactions to root canal disinfectants, even if the symptoms occur several hours after exposure. FAU - Jang, Ji Hoon AU - Jang JH AD - Department of Internal Medicine, Inje University Haeundae Paik Hospital, Busan, Korea. FAU - Park, Seung Hyun AU - Park SH AD - Department of Internal Medicine, Inje University Haeundae Paik Hospital, Busan, Korea. FAU - Jang, Hang Jea AU - Jang HJ AD - Department of Internal Medicine, Inje University Haeundae Paik Hospital, Busan, Korea. FAU - Lee, Sung Geun AU - Lee SG AD - Department of Internal Medicine, Inje University Haeundae Paik Hospital, Busan, Korea. FAU - Park, Jin Han AU - Park JH AD - Department of Internal Medicine, Inje University Haeundae Paik Hospital, Busan, Korea. FAU - Jeong, Jae Won AU - Jeong JW AD - Department of Internal Medicine, Inje University Ilsan Paik Hospital, Ilsan, Korea. FAU - Park, Chan Sun AU - Park CS AD - Department of Internal Medicine, Inje University Haeundae Paik Hospital, Busan, Korea. chansun@paik.ac.kr. LA - eng PT - Case Reports PL - Korea (South) TA - Yonsei Med J JT - Yonsei medical journal JID - 0414003 RN - 0 (Disinfectants) RN - 0 (Zinc Oxide-Eugenol Cement) RN - 0 (canals sealer) RN - 1HG84L3525 (Formaldehyde) RN - 37341-29-0 (Immunoglobulin E) SB - IM MH - Disinfectants/*adverse effects MH - Formaldehyde/*adverse effects MH - Humans MH - Hypersensitivity, Immediate/*chemically induced MH - Immunoglobulin E/*immunology MH - Male MH - Middle Aged MH - Recurrence MH - Skin Tests MH - Time Factors MH - Urticaria/*chemically induced/diagnosis MH - Zinc Oxide-Eugenol Cement/*chemistry PMC - PMC5122645 OTO - NOTNLM OT - Formaldehyde OT - type 1 hypersensitivity OT - urticaria COIS- The authors have no financial conflicts of interest. EDAT- 2016/11/23 06:00 MHDA- 2017/02/18 06:00 PMCR- 2017/01/01 CRDT- 2016/11/23 06:00 PHST- 2015/07/28 00:00 [received] PHST- 2015/12/03 00:00 [revised] PHST- 2015/12/10 00:00 [accepted] PHST- 2016/11/23 06:00 [entrez] PHST- 2016/11/23 06:00 [pubmed] PHST- 2017/02/18 06:00 [medline] PHST- 2017/01/01 00:00 [pmc-release] AID - 58.252 [pii] AID - 10.3349/ymj.2017.58.1.252 [doi] PST - ppublish SO - Yonsei Med J. 2017 Jan;58(1):252-254. doi: 10.3349/ymj.2017.58.1.252.