PMID- 28288430 OWN - NLM STAT- MEDLINE DCOM- 20170531 LR - 20221207 IS - 1879-1298 (Electronic) IS - 0045-6535 (Linking) VI - 177 DP - 2017 Jun TI - Rapid and sensitive on-line monitoring 6 different kinds of volatile organic compounds in aqueous samples by spray inlet proton transfer reaction mass spectrometry (SI-PTR-MS). PG - 217-223 LID - S0045-6535(17)30329-6 [pii] LID - 10.1016/j.chemosphere.2017.02.141 [doi] AB - Rapid and sensitive monitoring of volatile organic compounds (VOCs) in aqueous samples is very important to human health and environmental protection. In this study, an on-line spray inlet proton transfer reaction mass spectrometry (SI-PTR-MS) method was developed for the rapid and sensitive monitoring of 6 different kinds of VOCs, namely acetonitrile, acetaldehyde, ethanol, acetone, aether, and methylbenzene, in aqueous samples. The response time, limit of detection (LOD), and repeatability of the SI-PTR-MS system were evaluated. The response of the SI-PTR-MS was quite rapid with response times of 31-88 s. The LODs for all these VOCs were below 10 mug/L. The LOD of methylbenzene was 0.9 mug/L, much lower than the maximum contaminant level (MCL) in drinking water. The repeatability of this method was evaluated with 5 replicate determinations. The relative standard deviations (RSDs) were in the range of 0.8-3.1%, indicating good repeatability. To evaluate the matrix effects, the SI-PTR-MS system was employed for on-line monitoring of these 6 VOCs in different aqueous matrices, including lake water, tap water, and waste water. The relative recoveries were in the range of 94.6-106.0% for the lake water, 96.3-105.6% for the tap water, and 95.6-102.9% for the waste water. The results indicate that the SI-PTR-MS method has important application values in the rapid and sensitive monitoring of VOCs in these aqueous samples. In addition, the effect of salt concentration on the extracting efficiency was evaluated. The results showed that the LOD of the SI-PTR-MS could be further decreased by changing the salt concentration. CI - Copyright (c) 2017 Elsevier Ltd. All rights reserved. FAU - Zou, Xue AU - Zou X AD - Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, PR China; AnHui Province Key Laboratory of Medical Physics and Technology, Hefei, 230031, PR China. FAU - Kang, Meng AU - Kang M AD - Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, PR China; AnHui Province Key Laboratory of Medical Physics and Technology, Hefei, 230031, PR China. FAU - Wang, Hongmei AU - Wang H AD - Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei, 230031, PR China. FAU - Huang, Chaoqun AU - Huang C AD - Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, PR China; AnHui Province Key Laboratory of Medical Physics and Technology, Hefei, 230031, PR China. FAU - Shen, Chengyin AU - Shen C AD - Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, PR China; AnHui Province Key Laboratory of Medical Physics and Technology, Hefei, 230031, PR China. Electronic address: chyshen@aiofm.ac.cn. FAU - Chu, Yannan AU - Chu Y AD - Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, PR China; AnHui Province Key Laboratory of Medical Physics and Technology, Hefei, 230031, PR China. LA - eng PT - Journal Article DEP - 20170301 PL - England TA - Chemosphere JT - Chemosphere JID - 0320657 RN - 0 (Gases) RN - 0 (Salts) RN - 0 (Volatile Organic Compounds) RN - 0 (Waste Water) RN - 059QF0KO0R (Water) RN - 3FPU23BG52 (Toluene) SB - IM MH - Bays MH - Gases MH - Limit of Detection MH - Mass Spectrometry/*methods MH - Online Systems MH - Reproducibility of Results MH - Salts/chemistry MH - Spectrum Analysis MH - Toluene/analysis MH - Volatile Organic Compounds/*analysis MH - Wastewater/analysis MH - Water/*analysis MH - Water Purification/*methods OTO - NOTNLM OT - Aqueous samples OT - On-line monitoring OT - Proton transfer reaction mass spectrometry OT - Spray inlet OT - Volatile organic compounds EDAT- 2017/03/14 06:00 MHDA- 2017/06/01 06:00 CRDT- 2017/03/14 06:00 PHST- 2016/10/31 00:00 [received] PHST- 2017/02/08 00:00 [revised] PHST- 2017/02/27 00:00 [accepted] PHST- 2017/03/14 06:00 [pubmed] PHST- 2017/06/01 06:00 [medline] PHST- 2017/03/14 06:00 [entrez] AID - S0045-6535(17)30329-6 [pii] AID - 10.1016/j.chemosphere.2017.02.141 [doi] PST - ppublish SO - Chemosphere. 2017 Jun;177:217-223. doi: 10.1016/j.chemosphere.2017.02.141. Epub 2017 Mar 1.