PMID- 28772224 OWN - NLM STAT- MEDLINE DCOM- 20170926 LR - 20170926 IS - 1873-376X (Electronic) IS - 1570-0232 (Linking) VI - 1061-1062 DP - 2017 Sep 1 TI - Nanofibers mat-based solid-phase extraction method for the pretreatment of urine samples and its application in the primary study on the disposition of nonylphenol after long-term low-level exposure in rats. PG - 146-152 LID - S1570-0232(17)30570-6 [pii] LID - 10.1016/j.jchromb.2017.07.004 [doi] AB - A method was established for the analysis of nonylphenol (NP) in rat urine samples based on a solid-phase extraction (SPE) procedure with an amino functionalized polyacrylonitrile nanofibers mat (NH(2)-PAN NF(S)M) as sorbent coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The calibration curves prepared in three different days showed good linearity over a wide range of NP concentrations from 0.1 to 100.0ng/mL. It was remarkable that the proposed NH(2)-PAN NFsM based SPE method showed superior extraction efficiency with the consumption of only 4mg of sorbent and 500muL of eluent. The eluent without any further concentration was directly analyzed by HPLC-MS/MS. As a result, a simple and effective sample preparation was achieved. In addition, the notable lower detection limit (LOD) of 0.03ng/mL revealed the excellent sensitivity of the proposed method in comparison with that in literatures. The recoveries ranged from 85.0% to 114.8% with the relative standard deviations (RSDs) ranging from 7.5% to 13.7%, which were better than or comparable to those from the published methods, suggesting high accuracy of the proposed method. The proposed method was applied in primary study on the disposition of nonylphenol after long-term low-level exposure in rats, providing information for health risk assessment on the real scenarios of NP exposure. NH(2)-PAN NFsM shows great potential as a novel SPE sorbent for the analysis of biological samples. CI - Copyright (c) 2017 Elsevier B.V. All rights reserved. FAU - Qian, Liangliang AU - Qian L AD - Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China. FAU - Li, Ruixian AU - Li R AD - Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China. FAU - Di, Qiannan AU - Di Q AD - Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China. FAU - Shen, Yang AU - Shen Y AD - Department of Obstetrics and Gynecology, Zhong Da Hospital, School of Medicine, Southeast University, Nanjing 210009, China. FAU - Xu, Qian AU - Xu Q AD - Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China; Suzhou Key Laboratory of Environment and Biosafety, Suzhou 215123, China. Electronic address: q_xu68@163.com. FAU - Li, Jian AU - Li J AD - Su Zhou Municipal Center For Disease Prevention and Control, Suzhou 215004, China. Electronic address: 1055729273@qq.com. LA - eng PT - Journal Article DEP - 20170731 PL - Netherlands TA - J Chromatogr B Analyt Technol Biomed Life Sci JT - Journal of chromatography. B, Analytical technologies in the biomedical and life sciences JID - 101139554 RN - 0 (Phenols) RN - 79F6A2ILP5 (nonylphenol) SB - IM MH - Animals MH - Chromatography, High Pressure Liquid MH - Female MH - Limit of Detection MH - Linear Models MH - Nanofibers/*chemistry MH - Phenols/*urine MH - Rats MH - Rats, Sprague-Dawley MH - Reproducibility of Results MH - Solid Phase Extraction/*methods MH - Tandem Mass Spectrometry MH - Toxicity Tests, Chronic OTO - NOTNLM OT - Amino functionalized nanofibers mat OT - Biomonitoring OT - Long-term low level nonylphenol exposure OT - Rat urine samples OT - Solid-phase extraction EDAT- 2017/08/05 06:00 MHDA- 2017/09/28 06:00 CRDT- 2017/08/04 06:00 PHST- 2017/04/02 00:00 [received] PHST- 2017/06/02 00:00 [revised] PHST- 2017/07/02 00:00 [accepted] PHST- 2017/08/05 06:00 [pubmed] PHST- 2017/09/28 06:00 [medline] PHST- 2017/08/04 06:00 [entrez] AID - S1570-0232(17)30570-6 [pii] AID - 10.1016/j.jchromb.2017.07.004 [doi] PST - ppublish SO - J Chromatogr B Analyt Technol Biomed Life Sci. 2017 Sep 1;1061-1062:146-152. doi: 10.1016/j.jchromb.2017.07.004. Epub 2017 Jul 31.