PMID- 29983142 OWN - NLM STAT- MEDLINE DCOM- 20190520 LR - 20190520 IS - 2211-7466 (Electronic) IS - 2211-7458 (Linking) VI - 7 IP - 3 DP - 2018 Jul TI - Imaging Evaluation for the Detection of Leaflet Thrombosis After Transcatheter Aortic Valve Replacement. PG - 293-299 LID - S2211-7458(18)30021-X [pii] LID - 10.1016/j.iccl.2018.03.007 [doi] AB - Subclinical leaflet thrombosis has been increasingly recognized as a common imaging finding after surgical or transcatheter aortic valve replacement (TAVR) in recent studies. This finding has raised concerns over TAVR valve durability and debates on optimal postprocedural antithrombotic regime. Hypoattenuated leaflet thickening (HALT) and the associated reduced leaflet motion (RELM) were noted as computed tomography hallmarks of the phenomenon. The coexistence of HALT and significant RELM has been suggested as a threshold for reporting of subclinical leaflet thrombosis. This methodology may contribute to the standardization of reporting for research collaboration, hence the better understanding and management of this common yet largely unknown phenomenon. CI - Copyright (c) 2018 Elsevier Inc. All rights reserved. FAU - Zhao, Zhen-Gang AU - Zhao ZG AD - Heart Valve Center, New York University Langone Health, 530 1st Avenue, Suite 9V, New York, NY 10016, USA. FAU - Wang, Mo-Yang AU - Wang MY AD - Heart Valve Center, New York University Langone Health, 530 1st Avenue, Suite 9V, New York, NY 10016, USA. FAU - Jilaihawi, Hasan AU - Jilaihawi H AD - Heart Valve Center, New York University Langone Health, 530 1st Avenue, Suite 9V, New York, NY 10016, USA. Electronic address: hasanjilaihawi@gmail.com. LA - eng PT - Journal Article PT - Systematic Review DEP - 20180629 PL - Netherlands TA - Interv Cardiol Clin JT - Interventional cardiology clinics JID - 101615153 SB - IM MH - *Aortic Valve MH - Graft Occlusion, Vascular/diagnostic imaging/pathology MH - *Heart Valve Prosthesis MH - Humans MH - Postoperative Complications/*etiology MH - Prosthesis Failure MH - Thrombosis/diagnostic imaging/*etiology/pathology MH - Time-to-Treatment MH - Tomography, X-Ray Computed MH - Transcatheter Aortic Valve Replacement/*adverse effects OTO - NOTNLM OT - Hypoattenuated leaflet thickening OT - Hypoattenuation affecting motion OT - Leaflet thrombosis OT - Reduced leaflet motion OT - Transcatheter aortic valve replacement EDAT- 2018/07/10 06:00 MHDA- 2019/05/21 06:00 CRDT- 2018/07/10 06:00 PHST- 2018/07/10 06:00 [entrez] PHST- 2018/07/10 06:00 [pubmed] PHST- 2019/05/21 06:00 [medline] AID - S2211-7458(18)30021-X [pii] AID - 10.1016/j.iccl.2018.03.007 [doi] PST - ppublish SO - Interv Cardiol Clin. 2018 Jul;7(3):293-299. doi: 10.1016/j.iccl.2018.03.007. Epub 2018 Jun 29.