PMID- 30765129 OWN - NLM STAT- MEDLINE DCOM- 20190517 LR - 20190517 IS - 1873-3778 (Electronic) IS - 0021-9673 (Linking) VI - 1594 DP - 2019 Jun 7 TI - Column packing elimination in matrix solid phase dispersion by using water compatible magnetic molecularly imprinted polymer for recognition of melamine from milk samples. PG - 13-22 LID - S0021-9673(19)30145-1 [pii] LID - 10.1016/j.chroma.2019.02.015 [doi] AB - This paper reports a new variant of sample clean-up procedure based on miniaturized matrix solid phase dispersion (MSPD) combining with water compatible magnetic molecularly imprinted polymers (MMIP) for preconcentration of melamine from milk samples prior high-performance liquid chromatography with UV detection. By employing MMIP as dispersant sorbent matrix interferences could be eliminated completely and the column packing step was interestingly omitted that decreasing in glassware expenditure, labor effort and extraction time which cause improvement of the method performance. In order to investigate the functionality, morphology and magnetic properties of the prepared MMIP, it was fully characterized by FT-IR, VSM, SEM, and TEM. Multivariate optimization was applied as a versatile statistical approach for evaluating the influence of the main variables and their interactions on extraction efficiency. Under optimized conditions, the proposed method exhibited a wide linear response in the concentration range of 250.0-5000.0 mug L(-1), satisfactory recoveries for all samples (86.6%