PMID- 30824932 OWN - NLM STAT- MEDLINE DCOM- 20200701 LR - 20200701 IS - 1742-3406 (Electronic) IS - 0144-8420 (Linking) VI - 185 IP - 2 DP - 2019 Dec 23 TI - PATIENT DOSE SURVEY BASED ON SIZE-SPECIFIC DOSE ESTIMATE AND ACCEPTABLE QUALITY DOSE IN CHEST AND ABDOMEN/PELVIS CT EXAMINATIONS. PG - 176-182 LID - 10.1093/rpd/ncy288 [doi] AB - The practical aspects of two recently developed patient dose optimization methods in computed tomography (CT) examinations, size-specific dose estimate (SSDE) and acceptable quality dose (AQD), were verified for the chest and abdomen/pelvis examinations. A dose survey was performed in a CT institute by considering patients lateral diameter, weight and body mass index (BMI). The AQD tables for weight and BMI groups and SSDE threshold curves were obtained. The mean of volume CT dose index and dose length product for standard-size patients were compared with the national diagnostic reference levels (NDRLs) of Iran. The results show that patient doses are below the NDRLs. It is more reliable to report the AQDs based on SSDE and for BMI groups which can well take into account patient size in the dose optimization process. The SSDE threshold curves can be determined with more precision by including dose data of all possible sizes in the curves. CI - (c) The Author(s) 2019. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com. FAU - Mehdipour, Ali AU - Mehdipour A AD - Department of Radiology, Faculty of Paramedical, Rafsanjan University of Medical Sciences, PO BOX, Rafsanjan, Iran. FAU - Parsi, Masoumeh AU - Parsi M AD - Immunology of Infectious Diseases Research Center, Rafsanjan University of Medical Sciences, Rafsanjan, Iran. FAU - Khorram, Faezeh-Sadat AU - Khorram FS LA - eng PT - Journal Article PL - England TA - Radiat Prot Dosimetry JT - Radiation protection dosimetry JID - 8109958 SB - IM MH - Adolescent MH - Adult MH - Aged MH - Aged, 80 and over MH - Body Mass Index MH - Body Size MH - Body Weight MH - Humans MH - Image Processing, Computer-Assisted/methods MH - Iran MH - Middle Aged MH - Neoplasms/*diagnostic imaging/pathology MH - Pelvis/*diagnostic imaging MH - Quality Assurance, Health Care/*standards MH - Radiation Dosage MH - Radiography, Abdominal/*methods MH - Radiography, Thoracic/*methods MH - *Surveys and Questionnaires MH - Tomography, X-Ray Computed/*methods MH - Young Adult EDAT- 2019/03/03 06:00 MHDA- 2020/07/02 06:00 CRDT- 2019/03/03 06:00 PHST- 2018/04/03 00:00 [received] PHST- 2018/12/01 00:00 [revised] PHST- 2019/01/02 00:00 [accepted] PHST- 2019/03/03 06:00 [pubmed] PHST- 2020/07/02 06:00 [medline] PHST- 2019/03/03 06:00 [entrez] AID - 5368224 [pii] AID - 10.1093/rpd/ncy288 [doi] PST - ppublish SO - Radiat Prot Dosimetry. 2019 Dec 23;185(2):176-182. doi: 10.1093/rpd/ncy288.