PMID- 30826652 OWN - NLM STAT- MEDLINE DCOM- 20190710 LR - 20190710 IS - 1873-4235 (Electronic) IS - 0956-5663 (Linking) VI - 131 DP - 2019 Apr 15 TI - A sensitive sandwich-type immunosensor for the detection of MCP-1 based on a rGO-TEPA-Thi-Au nanocomposite and novel RuPdPt trimetallic nanoalloy particles. PG - 67-73 LID - S0956-5663(19)30124-1 [pii] LID - 10.1016/j.bios.2019.02.021 [doi] AB - A novel electrochemical immunosensor was proposed for the detection of monocyte chemoattractant protein-1 (MCP-1), a biomarker of cardiovascular disease. Due to thionine (Thi) possessing electroactive redox properties, a one-step approach was utilized to synthesize a reduced graphene oxide-tetraethylene-thionine-Au (rGO-TEPA-Thi-Au) nanocomposite at room temperature using the synergistic effect of Thi and rGO-TEPA towards HAuCl(4). We obtained the excellent matrix material, which immobilized more primary antibody MCP-1-Ab(1) on rGO-TEPA on a modified glassy carbon electrode (GCE). To further enhance the sensitivity of the sensor, a novel signal generation and amplification strategy was developed for detection. RuPdPt trimetallic nanoalloy particles (RuPdPt TNPs), a novel nanomaterial, were synthesized by a one-pot method, displayed a uniform morphology as well as good electrochemical activity and bound with the secondary antibodies against MCP-1 via the Pt-NH(2) bond. Most importantly, RuPdPt TNPs have a significant ability to catalyze H(2)O(2) to produce an electron. The electrochemical signal was highly amplified because the electrochemical signal was primarily derived from the synergistic catalysis of H(2)O(2) by RuPdPt TNPs and recorded by chronoamperometry. Under the optimal conditions, this newly designed biosensor exhibited sensitive detection of MCP-1 in the range from 20 fg mL(-1) to 1000 pg mL(-1), with a detection limit of 8.9 fg mL(-1) (based on a S/N = 3). Additionally, the designed immunosensor showed acceptable selectivity, reproducibility and stability. This immunosensor is a promising strategy for analyzing clinical serum samples in the future. CI - Copyright (c) 2019 Elsevier B.V. All rights reserved. FAU - Mao, Weiran AU - Mao W AD - College of Pharmacy, Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China. FAU - He, Junlin AU - He J AD - College of Pharmacy, Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China. FAU - Tang, Zhiyong AU - Tang Z AD - College of Pharmacy, Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China. FAU - Zhang, Chengli AU - Zhang C AD - College of Pharmacy, Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China. FAU - Chen, Jun AU - Chen J AD - College of Pharmacy, Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China. FAU - Li, Jia AU - Li J AD - College of Pharmacy, Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China. FAU - Yu, Chao AU - Yu C AD - College of Pharmacy, Institute of Life Science and School of Public Health, Chongqing Medical University, Chongqing 400016, PR China. Electronic address: yuchao@cqmu.edu.cn. LA - eng PT - Journal Article DEP - 20190219 PL - England TA - Biosens Bioelectron JT - Biosensors & bioelectronics JID - 9001289 RN - 0 (Antibodies, Immobilized) RN - 0 (CCL2 protein, human) RN - 0 (Chemokine CCL2) RN - 49DFR088MY (Platinum) RN - 7440-57-5 (Gold) RN - 7782-42-5 (Graphite) RN - BBX060AN9V (Hydrogen Peroxide) SB - IM MH - Antibodies, Immobilized/chemistry/isolation & purification MH - *Biosensing Techniques MH - Chemokine CCL2/chemistry/*isolation & purification MH - *Electrochemical Techniques MH - Gold/chemistry MH - Graphite/chemistry MH - Humans MH - Hydrogen Peroxide/chemistry MH - Limit of Detection MH - Metal Nanoparticles/*chemistry MH - Nanocomposites/chemistry MH - Platinum/chemistry OTO - NOTNLM OT - Immunosensor OT - Monocyte chemoattractant protein-1 OT - Tetraethylene OT - Thionine OT - Trimetallic nanoalloy particles EDAT- 2019/03/04 06:00 MHDA- 2019/07/11 06:00 CRDT- 2019/03/04 06:00 PHST- 2018/10/28 00:00 [received] PHST- 2018/12/10 00:00 [revised] PHST- 2019/02/05 00:00 [accepted] PHST- 2019/03/04 06:00 [pubmed] PHST- 2019/07/11 06:00 [medline] PHST- 2019/03/04 06:00 [entrez] AID - S0956-5663(19)30124-1 [pii] AID - 10.1016/j.bios.2019.02.021 [doi] PST - ppublish SO - Biosens Bioelectron. 2019 Apr 15;131:67-73. doi: 10.1016/j.bios.2019.02.021. Epub 2019 Feb 19.