PMID- 31025153 OWN - NLM STAT- MEDLINE DCOM- 20200109 LR - 20200225 IS - 1572-8595 (Electronic) IS - 1383-875X (Linking) VI - 55 IP - 1 DP - 2019 Jun TI - Effects of implantation of quadripolar left ventricular leads on CRT response. PG - 73-81 LID - 10.1007/s10840-019-00545-8 [doi] AB - BACKGROUND: The use of quadripolar (QP) left ventricular leads for cardiac resynchronization therapy (CRT) is intended to improve outcomes compared with conventional bipolar leads (BP). Hence, the number of implanted quadripolar CRT systems is increasing despite limited long-term data. PURPOSE: The aim of this study is to evaluate clinical response and long-term outcomes of CRT recipients who were implanted with quadripolar versus bipolar left ventricular leads. METHODS: Data from consecutive patients receiving a CRT defibrillator in one German and one Hungarian tertiary referral center were retrospectively collected. Long-term survival and response to CRT were analyzed. RESULTS: A total of 536 patients with structural heart disease and a mean left ventricular ejection fraction (LVEF) of 25% received a CRT defibrillator (CRT-D) system for primary (79%) or secondary (21%) prevention of sudden death. Comorbidities did not differ significantly between patients receiving a QP (n = 123) or a BP lead (n = 413). Procedure (101 vs. 120 min) and fluoroscopy times (14 vs. 20 min) were shorter in patients implanted with QP compared with BP (both p < 0.001). At 6 months follow-up, QP patients were more likely to respond to CRT measured as improvement in the New York Heart Association (NYHA) functional class (77% vs. 63%; p < 0.001). Use of QP left ventricle/left ventricular (LV) leads was associated with greater reduction in QRS duration compared with patients implanted with BP LV leads (- 21 +/- 30 vs. - 8 +/- 35 ms, p = 0.004). Mortality was not significantly different between patients with QP and patients with BP LV leads at a mean follow-up of 39 +/- 31 months. CONCLUSION: Implantation of quadripolar left ventricular leads was associated with better CRT response compared with bipolar left ventricular leads. FAU - Erath, Julia W AU - Erath JW AUID- ORCID: 0000-0003-3145-6767 AD - Department of Cardiology, Division of Clinical Electrophysiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany. FAU - Vamos, Mate AU - Vamos M AD - Department of Cardiology, Division of Clinical Electrophysiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany. FAU - Domokos, Dominika AU - Domokos D AD - Department of Cardiology, Medical Centre, Hungarian Defence Forces, Budapest, Hungary. FAU - Benz, Alexander P AU - Benz AP AD - Department of Cardiology, Division of Clinical Electrophysiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany. FAU - Bari, Zsolt AU - Bari Z AD - Department of Cardiology, Medical Centre, Hungarian Defence Forces, Budapest, Hungary. FAU - Bogyi, Peter AU - Bogyi P AD - Department of Cardiology, Medical Centre, Hungarian Defence Forces, Budapest, Hungary. FAU - Duray, Gabor Z AU - Duray GZ AD - Department of Cardiology, Medical Centre, Hungarian Defence Forces, Budapest, Hungary. FAU - Hohnloser, Stefan H AU - Hohnloser SH AD - Department of Cardiology, Division of Clinical Electrophysiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt, Germany. hohnloser@em.uni-frankfurt.de. LA - eng PT - Journal Article PT - Multicenter Study DEP - 20190425 PL - Netherlands TA - J Interv Card Electrophysiol JT - Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing JID - 9708966 SB - IM MH - Aged MH - *Cardiac Resynchronization Therapy Devices MH - *Electrodes, Implanted MH - Equipment Design MH - Female MH - Germany MH - Humans MH - Hungary MH - Male MH - Retrospective Studies MH - Survival Rate OTO - NOTNLM OT - Bipolar lead OT - CRT OT - CRT-D OT - Cardiac resynchronization therapy OT - Quadripolar lead OT - Response EDAT- 2019/04/27 06:00 MHDA- 2020/01/10 06:00 CRDT- 2019/04/27 06:00 PHST- 2018/12/23 00:00 [received] PHST- 2019/03/26 00:00 [accepted] PHST- 2019/04/27 06:00 [pubmed] PHST- 2020/01/10 06:00 [medline] PHST- 2019/04/27 06:00 [entrez] AID - 10.1007/s10840-019-00545-8 [pii] AID - 10.1007/s10840-019-00545-8 [doi] PST - ppublish SO - J Interv Card Electrophysiol. 2019 Jun;55(1):73-81. doi: 10.1007/s10840-019-00545-8. Epub 2019 Apr 25.