PMID- 31365947 OWN - NLM STAT- MEDLINE DCOM- 20200603 LR - 20200603 IS - 1438-8812 (Electronic) IS - 0013-726X (Linking) VI - 51 IP - 9 DP - 2019 Sep TI - Endoscopic ultrasound-guided liver biopsy using a 22-G fine needle biopsy needle: a prospective study. PG - 818-824 LID - 10.1055/a-0967-3640 [doi] AB - BACKGROUND: Endoscopic ultrasound-guided liver biopsy (EUS-LB) using a 19-gauge (19-G) EUS needle is becoming increasingly popular. We evaluated the efficacy and safety of a 22-G EUS fine needle biopsy (FNB) needle for performing EUS-LB. METHODS: Patients referred for evaluation of elevated liver enzymes and without obstructive disease requiring endoscopic retrograde cholangiopancreatography (ERCP) were included. Using a 22-G FNB needle, two passes were made from the left lobe and one from the right. The main outcome measure was adequacy of the specimen for histology interpretation, and the secondary outcome was the safety of EUS-guided liver biopsy with a 22-G FNB needle. Patients were followed for post-procedure complications for 30 days. RESULTS: 40 patients (median age 61 years; 26 women) underwent EUS-LB. Analyzing by needle passes, the median longest core fragment was 12 mm (1st quartile - 3rd quartile 10 mm - 16.25 mm, interquartile range [IQR] 6.25 mm) from the left lobe and 11 mm (10 mm - 15.75 mm, IQR 5.75 mm) from the right lobe. The median cumulative core length per patient was 55 mm (44.5 mm - 68 mm, IQR 23.5 mm). The median cumulative number of complete portal triads (CPTs) per patient was 42 (28.5 - 53, IQR 24.5). The specimen was considered adequate in all 40 patients (100 %). Self-limiting abdominal pain was reported in 6 patients (15 %). CONCLUSIONS: EUS-LB using a 22-G FNB needle is a safe and viable alternative to the use of larger gauge needles, yielding adequate tissue for evaluation of parenchymal disease in 100 % of the patients. CI - (c) Georg Thieme Verlag KG Stuttgart . New York. FAU - Hasan, Muhammad K AU - Hasan MK AD - Center for Interventional Endoscopy, AdventHealth Orlando, Florida, USA. FAU - Kadkhodayan, Kambiz AU - Kadkhodayan K AD - Center for Interventional Endoscopy, AdventHealth Orlando, Florida, USA. FAU - Idrisov, Evgeny AU - Idrisov E AD - Department of Internal Medicine, AdventHealth Orlando, Florida, USA. FAU - Ali, Saeed AU - Ali S AD - Department of Internal Medicine, AdventHealth Orlando, Florida, USA. FAU - Rafiq, Ehsan AU - Rafiq E AD - Department of Gastroenterology and Hepatology, AdventHealth Orlando, Florida, USA. FAU - Ben-Ami Shor, Dana AU - Ben-Ami Shor D AD - Center for Interventional Endoscopy, AdventHealth Orlando, Florida, USA. AD - Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel. FAU - Abdel-Jalil, Ala AU - Abdel-Jalil A AD - Center for Interventional Endoscopy, AdventHealth Orlando, Florida, USA. FAU - Navaneethan, Uday AU - Navaneethan U AD - Center for Interventional Endoscopy, AdventHealth Orlando, Florida, USA. FAU - Bang, Ji AU - Bang J AD - Center for Interventional Endoscopy, AdventHealth Orlando, Florida, USA. FAU - Varadarajulu, Shyam AU - Varadarajulu S AD - Center for Interventional Endoscopy, AdventHealth Orlando, Florida, USA. FAU - Hawes, Robert AU - Hawes R AD - Center for Interventional Endoscopy, AdventHealth Orlando, Florida, USA. FAU - Pernicone, Peter AU - Pernicone P AD - Department of Pathology, AdventHealth Orlando, Florida, USA. LA - eng PT - Journal Article DEP - 20190731 PL - Germany TA - Endoscopy JT - Endoscopy JID - 0215166 SB - IM CIN - Endoscopy. 2019 Sep;51(9):811-812. PMID: 31461770 CIN - Endoscopy. 2019 Sep;51(9):903. PMID: 31461774 CIN - Endoscopy. 2020 Feb;52(2):157. PMID: 31991474 CIN - Endoscopy. 2020 Feb;52(2):158. PMID: 31991475 MH - Abdominal Pain/epidemiology MH - Endoscopic Ultrasound-Guided Fine Needle Aspiration/adverse effects/*instrumentation MH - Endosonography MH - Female MH - Humans MH - Liver Diseases/diagnostic imaging/*pathology MH - Male MH - Middle Aged MH - *Needles MH - Pain, Postoperative/epidemiology MH - Prospective Studies COIS- The following authors disclosed financial relationships relevant to this publication. Muhammad K. Hasan is a consultant for Boston Scientific and Olympus America. Robert Hawes is a consultant for Boston Scientific, Olympus America, and Medtronic. Shyam Varadarajulu is a consultant for Boston Scientific and Olympus America. All other authors disclosed no financial relationships relevant to this publication. EDAT- 2019/08/01 06:00 MHDA- 2020/06/04 06:00 CRDT- 2019/08/01 06:00 PHST- 2019/08/01 06:00 [pubmed] PHST- 2020/06/04 06:00 [medline] PHST- 2019/08/01 06:00 [entrez] AID - 10.1055/a-0967-3640 [doi] PST - ppublish SO - Endoscopy. 2019 Sep;51(9):818-824. doi: 10.1055/a-0967-3640. Epub 2019 Jul 31.