PMID- 31659511 OWN - NLM STAT- PubMed-not-MEDLINE LR - 20200928 IS - 2090-911X (Electronic) IS - 1110-2608 (Print) IS - 1110-2608 (Linking) VI - 71 IP - 1 DP - 2019 Aug 5 TI - Assessment of left ventricular systolic function after VSD transcatheter device closure using speckle tracking echocardiography. PG - 1 LID - 10.1186/s43044-019-0001-7 [doi] LID - 1 AB - BACKGROUND: This is a case-control study conducted on 30 children, 15 with VSD who performed VSD transcatheter device closure (group A) and 15 controls of matching age and gender (group B), in the period between September 2015 and February 2018. We aimed to assess the global left ventricular (LV) systolic function by 2D speckle tracking before and after ventricular septal defect (VSD) transcatheter closure, in comparison to normal controls. All patients were subjected to full history taking; general and cardiac examination; ECG; CXR; full transthoracic echocardiographic examination, including VSD number, size, and site; LV dimensions and volumes; estimated pulmonary artery pressure; right ventricular size and function; left ventricular circumferential; and radial strain imaging by 2D speckle tracking. Patients who had ventricular septal defect closed were reassessed by transthoracic echocardiography after 3 months. RESULTS: The study included 15 children with VSD: 3 males and 12 females; their age ranged from 2 to 13 years; all had subaortic VSD except for 1 who had apical muscular VSD: VSD size ranged from 3 to 8 mm; PFM coil was used to close defect in all patients except for 2 patients who had an Amplatzer duct occlude I (ADOI) device, and 1 patient needed an additional vascular plug after significant hemolysis. Pre-procedurally, group A had a significantly higher LVEDD, LVESD, and LVEDV than group B. Mean circumferential strain was significantly higher (more negative) in group A than that in group B either pre- or post-procedure. Post-procedurally, there was a significant decrease in circumferential strain (less negative) and a significant increase in radial strain (more positive). CONCLUSION: Following transcatheter VSD closure, there is a significant decrease in LV circumferential strain and a significant increase in LV radial strain, which conclude a decrease in LV volume overload with the improvement of its contractility. FAU - Ali, Yasmin Abdelrazek AU - Ali YA AD - Ain Shams University, Cairo, 11528, Egypt. yasminabdelrazek@med.asu.edu.eg. FAU - Hassan, Maryam Araby AU - Hassan MA AD - Ain Shams University, Cairo, 11528, Egypt. FAU - El Fiky, Azza Abdallah AU - El Fiky AA AD - Ain Shams University, Cairo, 11528, Egypt. LA - eng PT - Journal Article DEP - 20190805 PL - Germany TA - Egypt Heart J JT - The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology JID - 9106952 PMC - PMC6821406 OTO - NOTNLM OT - 2D strain OT - Speckle tracking OT - Transcatheter VSD closure OT - Ventricular septal defect COIS- The authors declare that they have no competing interests. EDAT- 2019/10/30 06:00 MHDA- 2019/10/30 06:01 PMCR- 2019/08/05 CRDT- 2019/10/30 06:00 PHST- 2019/05/27 00:00 [received] PHST- 2019/06/21 00:00 [accepted] PHST- 2019/10/30 06:00 [entrez] PHST- 2019/10/30 06:00 [pubmed] PHST- 2019/10/30 06:01 [medline] PHST- 2019/08/05 00:00 [pmc-release] AID - 10.1186/s43044-019-0001-7 [pii] AID - 1 [pii] AID - 10.1186/s43044-019-0001-7 [doi] PST - epublish SO - Egypt Heart J. 2019 Aug 5;71(1):1. doi: 10.1186/s43044-019-0001-7.