PMID- 31811559 OWN - NLM STAT- Publisher LR - 20240227 IS - 1879-5447 (Electronic) IS - 0158-9938 (Linking) DP - 2019 Dec 6 TI - Size-specific dose estimates for various weighting factors of CTDI equation. LID - 10.1007/s13246-019-00830-w [doi] AB - Size-specific dose estimate (SSDE) was proposed by the American Association of Physicists in Medicine (AAPM) Task Group 204 to consider the effect of patient size in the x-ray CT dose estimation. Size correction factors to calculate SSDE were derived based on the conventional weighted CT dose index (CTDI(w)) equation. This study aims to investigate the influence of Bakalyar's and the authors' own CTDI(w) equations on the size correction factors described by the AAPM Task Group 204, using Monte Carlo simulations. The simulations were performed by modeling four types of x-ray CT scanner designs, to compute the dose values in water for cylindrical phantoms with 8-40 cm diameters. CTDI(100) method and the AAPM Task Group 111's proposed method were employed as the CT dosimetry models. Size correction factors were obtained for the computed dose values of various phantom diameters for the conventional, Bakalyar's, and the authors' weighting factors. Maximum difference between the size correction factors for the Bakalyar's weighting factor and those of the AAPM Task Group 204 was 27% for a phantom diameter of 11.2 cm. On the other hand, the size correction factors calculated for the authors' weighting factor were in good agreement with those from the AAPM Task Group 204 report with a maximum difference of 17%. The results indicate that the SSDE values obtained with the authors' weighting factor can be evaluated by using the size correction factors reported by the AAPM Task Group 204, which is currently accepted as a standard. FAU - Haba, Tomonobu AU - Haba T AUID- ORCID: 0000-0002-5257-6162 AD - Faculty of Radiological TechnologySchool of Medical Science, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, Japan. habatomo@fujita-hu.ac.jp. FAU - Kobayashi, Masanao AU - Kobayashi M AD - Faculty of Radiological TechnologySchool of Medical Science, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, Japan. FAU - Koyama, Shuji AU - Koyama S AD - Brain & Mind Research Center, Nagoya University, 1-1-20 Daiko-Minami, Higashi-ku, Nagoya, Aichi, Japan. LA - eng PT - Journal Article DEP - 20191206 PL - Netherlands TA - Australas Phys Eng Sci Med JT - Australasian physical & engineering sciences in medicine JID - 8208130 SB - IM OTO - NOTNLM OT - AAPM task group 111 OT - AAPM task group 204 OT - Monte carlo simulation OT - Size-specific dose estimate OT - Weighted CTDI EDAT- 2019/12/08 06:00 MHDA- 2019/12/08 06:00 CRDT- 2019/12/08 06:00 PHST- 2019/08/17 00:00 [received] PHST- 2019/12/02 00:00 [accepted] PHST- 2019/12/08 06:00 [entrez] PHST- 2019/12/08 06:00 [pubmed] PHST- 2019/12/08 06:00 [medline] AID - 10.1007/s13246-019-00830-w [pii] AID - 10.1007/s13246-019-00830-w [doi] PST - aheadofprint SO - Australas Phys Eng Sci Med. 2019 Dec 6. doi: 10.1007/s13246-019-00830-w.