PMID- 33159449 OWN - NLM STAT- MEDLINE DCOM- 20210623 LR - 20210623 IS - 1742-3406 (Electronic) IS - 0144-8420 (Linking) VI - 191 IP - 3 DP - 2020 Dec 3 TI - DEVELOPMENT OF A SPECIALISED TAPE MEASURE TO ESTIMATE THE SIZE-SPECIFIC DOSE ESTIMATE. PG - 369-375 LID - 10.1093/rpd/ncaa133 [doi] AB - The risk in computed tomography (CT) examinations is radiation exposure. We aimed to develop a specialised tape measure for determining the size-specific dose estimate (SSDE) for patients undergoing CT scans. The scanning parameters used were those of the abdominal protocol in our institute. With this method, the SSDE220 and standard deviations obtained from CT images for the liver, pelvic and lung areas, corresponded closely to the SSDEtape and standard deviations obtained using the tape measure. We thus devised a new idea that allows the estimation of the SSDE220 using a specialised tape measure before the CT examination, allowing for an informed explanation of the radiation dose to the patient. Although the tape measure developed in this study is specific to one particular CT instrument, the method could be adapted to a wide range of radiography applications. CI - (c) The Author(s) 2020. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com. FAU - Shohji, Tomokazu AU - Shohji T AD - Department of Radiology, The Jikei University Kashiwa Hospital, 3-19-18 Nishi-Shimbashi, Minato-ku, Tokyo, 105-8471 Japan. FAU - Kuriyama, Kazuki AU - Kuriyama K AD - Department of Radiology, The Jikei University Kashiwa Hospital, 163-1 Kashiwashita, Kashiwa-shi, Chiba 277-8567, Japan. FAU - Yanano, Nobutaka AU - Yanano N AD - Department of Radiology, The Jikei University Kashiwa Hospital, 163-1 Kashiwashita, Kashiwa-shi, Chiba 277-8567, Japan. FAU - Katoh, Yo AU - Katoh Y AD - Department of Radiological Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-Ogu, Arakawa-ku, Tokyo 116-8551, Japan. LA - eng PT - Journal Article PL - England TA - Radiat Prot Dosimetry JT - Radiation protection dosimetry JID - 8109958 SB - IM MH - Abdomen/diagnostic imaging MH - Humans MH - Pelvis MH - Radiation Dosage MH - *Radiation Exposure MH - Tomography, X-Ray Computed EDAT- 2020/11/08 06:00 MHDA- 2021/06/24 06:00 CRDT- 2020/11/07 08:34 PHST- 2020/04/26 00:00 [received] PHST- 2020/09/06 00:00 [revised] PHST- 2020/09/07 00:00 [accepted] PHST- 2020/11/08 06:00 [pubmed] PHST- 2021/06/24 06:00 [medline] PHST- 2020/11/07 08:34 [entrez] AID - 5959939 [pii] AID - 10.1093/rpd/ncaa133 [doi] PST - ppublish SO - Radiat Prot Dosimetry. 2020 Dec 3;191(3):369-375. doi: 10.1093/rpd/ncaa133.