PMID- 33801087 OWN - NLM STAT- PubMed-not-MEDLINE LR - 20240331 IS - 2077-0383 (Print) IS - 2077-0383 (Electronic) IS - 2077-0383 (Linking) VI - 10 IP - 6 DP - 2021 Mar 21 TI - Application of Pelvic Circumferential Compression Devices in Pelvic Ring Fractures-Are Guidelines Followed in Daily Practice? LID - 10.3390/jcm10061297 [doi] LID - 1297 AB - Early administration of a pelvic circumferential compression device (PCCD) is recommended for suspected pelvic trauma. This study was conducted to evaluate the prevalence of PCCD in patients with pelvic fractures assigned to the resuscitation room (RR) of a Level I trauma center. Furthermore, correct application of the PCCD as well as associated injuries with potential clinical sequelae were assessed. All patients with pelvic fractures assigned to the RR of a level one trauma center between 2016 and 2017 were evaluated retrospectively. Presence and position of the PCCD on the initial trauma scan were assessed and rated. Associated injuries with potential adverse effects on clinical outcome were analysed. Seventy-seven patients were included, of which 26 (34%) had a PCCD in place. Eighteen (23%) patients had an unstable fracture pattern of whom ten (56%) had received a PCCD. The PCCD was correctly placed in four (15%) cases, acceptable in 12 (46%) and incorrectly in ten (39%). Of all patients with pelvic fractures (n = 77, 100%) treated in the RR, only one third (n = 26, 34%) had a PCCD. In addition, 39% of PCCDs were positioned incorrectly. Of the patients with unstable pelvic fractures (n = 18, 100%), more than half either did not receive any PCCD (n = 8, 44%) or had one which was inadequately positioned (n = 2, 11 %). These results underline that preclinical and clinical education programs on PCCD indication and application should be critically reassessed. FAU - Kuner, Valerie AU - Kuner V AUID- ORCID: 0000-0001-6094-1230 AD - Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne, 6000 Luzern, Switzerland. FAU - van Veelen, Nicole AU - van Veelen N AUID- ORCID: 0000-0002-9159-5382 AD - Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne, 6000 Luzern, Switzerland. FAU - Studer, Stephanie AU - Studer S AD - Medical Faculty, University of Zurich, 8091 Zurich, Switzerland. FAU - Van de Wall, Bryan AU - Van de Wall B AD - Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne, 6000 Luzern, Switzerland. FAU - Fornaro, Jurgen AU - Fornaro J AD - Department of Radiology, Cantonal Hospital Lucerne, 6000 Luzern, Switzerland. FAU - Stickel, Michael AU - Stickel M AD - Department of Emergency Care, Cantonal Hospital Lucerne, 6000 Luzern, Switzerland. FAU - Knobe, Matthias AU - Knobe M AUID- ORCID: 0000-0002-9166-0965 AD - Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne, 6000 Luzern, Switzerland. FAU - Babst, Reto AU - Babst R AUID- ORCID: 0000-0002-7606-1358 AD - Department of Health Science and Medicine, University of Lucerne, 6002 Luzern, Switzerland. FAU - Beeres, Frank J P AU - Beeres FJP AD - Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne, 6000 Luzern, Switzerland. FAU - Link, Bjorn-Christian AU - Link BC AUID- ORCID: 0000-0002-3289-6935 AD - Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne, 6000 Luzern, Switzerland. LA - eng PT - Journal Article DEP - 20210321 PL - Switzerland TA - J Clin Med JT - Journal of clinical medicine JID - 101606588 PMC - PMC8003916 OTO - NOTNLM OT - PCCD OT - associated injuries OT - pelvic ring fracture OT - position COIS- The authors declare no conflict of interest. EDAT- 2021/04/04 06:00 MHDA- 2021/04/04 06:01 PMCR- 2021/03/21 CRDT- 2021/04/03 01:07 PHST- 2021/02/14 00:00 [received] PHST- 2021/03/09 00:00 [revised] PHST- 2021/03/18 00:00 [accepted] PHST- 2021/04/03 01:07 [entrez] PHST- 2021/04/04 06:00 [pubmed] PHST- 2021/04/04 06:01 [medline] PHST- 2021/03/21 00:00 [pmc-release] AID - jcm10061297 [pii] AID - jcm-10-01297 [pii] AID - 10.3390/jcm10061297 [doi] PST - epublish SO - J Clin Med. 2021 Mar 21;10(6):1297. doi: 10.3390/jcm10061297.