PMID- 34516579 OWN - NLM STAT- MEDLINE DCOM- 20211123 LR - 20211123 IS - 1932-6203 (Electronic) IS - 1932-6203 (Linking) VI - 16 IP - 9 DP - 2021 TI - Size-specific dose estimates of adult, chest computed tomography examinations: Comparison of Chinese and updated 2017 American College of Radiology diagnostic reference levels based on the water-equivalent diameter. PG - e0257294 LID - 10.1371/journal.pone.0257294 [doi] LID - e0257294 AB - RATIONALE AND OBJECTIVES: This study aimed to compare the volume computed tomography dose index (CTDIvol), dose length product (DLP), and size-specific dose estimate (SSDE), with the China and updated 2017 American College of Radiology (ACR) diagnostic reference levels (DRLs) in chest CT examinations of adults based on the water-equivalent diameter (Dw). MATERIALS AND METHODS: All chest CT examinations conducted without contrast administration from January 2020 to July 2020 were retrospectively included in this study. The Dw and SSDE of all examinations were calculated automatically by "teamplay". The CTDIvol and DLP were displayed on the DICOM-structured dose report in the console based on a 32cm phantom.The differences in patient CTDIvol, DLP, and SSDE values between groups were examined by the one-way ANOVA. The differences in patient CTDIvol, DLP, and SSDE values between the updated 2017 ACR and the China DRLs were examined with one sample t-tests. RESULTS: In total 14666 chest examinations were conducted in our study. Patients were divided into four groups based on Dw:270 (1.84%) in 15-20 cm group, 10287 (70.14%) in the 21-25 cm group, 4097 (27.94%) in the 26-30 cm group, and 12 (0.08%) patients had sizes larger than 30 cm. CTDIvol, DLP, and SSDE increased as a function of Dw (p<0.05). CTDIvol was smaller than SSDE among groups (p<0.05). The mean CTDIvol and DLP values were lower than the 25th, 50th, and 75th percentile of the China DRLs (p <0.05). The CTDIvol, DLP, and SSDE were lower than the 50th and 75th percentiles of the updated 2017 ACR DRLs (p <0.05) among groups. CONCLUSIONS: SSDE takes into account the influence of the scanning parameters, patient size, and X-ray attenuation on the radiation dose, which can give a more realistic estimate of radiation exposure dose for patients undergoing CT examinations. Establishing hospital's own DRL according to CTDIvol and SSDE is very important even though the radiation dose is lower than the national DRLs. FAU - Hu, Xiaoyan AU - Hu X AUID- ORCID: 0000-0002-5148-2068 AD - Department of Radiology, Chengdu First People's Hospital, Chengdu, Sichuan Province, China. FAU - Gou, Jie AU - Gou J AD - Department of Radiology, Chengdu First People's Hospital, Chengdu, Sichuan Province, China. FAU - Lin, Wei AU - Lin W AD - Department of Radiology, Chengdu First People's Hospital, Chengdu, Sichuan Province, China. FAU - Zou, Chunhua AU - Zou C AD - Department of Radiology, Chengdu First People's Hospital, Chengdu, Sichuan Province, China. FAU - Li, Wenbo AU - Li W AUID- ORCID: 0000-0003-2593-6131 AD - Department of Radiology, Chengdu First People's Hospital, Chengdu, Sichuan Province, China. LA - eng PT - Journal Article DEP - 20210913 PL - United States TA - PLoS One JT - PloS one JID - 101285081 SB - IM MH - Adult MH - China MH - Diagnostic Reference Levels MH - Female MH - Humans MH - Male MH - Middle Aged MH - Radiation Dosage MH - Reference Values MH - Retrospective Studies MH - Tomography, X-Ray Computed/*methods/standards PMC - PMC8437305 COIS- The authors have declared that no competing interests exist. EDAT- 2021/09/14 06:00 MHDA- 2021/11/24 06:00 PMCR- 2021/09/13 CRDT- 2021/09/13 17:28 PHST- 2021/03/08 00:00 [received] PHST- 2021/08/28 00:00 [accepted] PHST- 2021/09/13 17:28 [entrez] PHST- 2021/09/14 06:00 [pubmed] PHST- 2021/11/24 06:00 [medline] PHST- 2021/09/13 00:00 [pmc-release] AID - PONE-D-21-05170 [pii] AID - 10.1371/journal.pone.0257294 [doi] PST - epublish SO - PLoS One. 2021 Sep 13;16(9):e0257294. doi: 10.1371/journal.pone.0257294. eCollection 2021.