PMID- 35699203 OWN - NLM STAT- MEDLINE DCOM- 20220810 LR - 20220811 IS - 1526-9914 (Electronic) IS - 1526-9914 (Linking) VI - 23 IP - 8 DP - 2022 Aug TI - The effect of material assignment in nasal cavity on dose calculation for nasopharyngeal carcinoma (NPC) using Acuros XB. PG - e13698 LID - 10.1002/acm2.13698 [doi] LID - e13698 AB - PURPOSE: To evaluate the effect of material assignment in nasal cavity on dose calculation for the volumetric modulated arc therapy (VMAT) of nasopharyngeal carcinoma (NPC) using Acuros XB (AXB) algorithm. METHODS: The VMAT plans of 30 patients with NPC were calculated using AXB with material auto-assignment of nasal cavity to lung and reassignment to air respectively. The doses to the planning target volumes (PTVs) overlapping with nasal cavity with material auto-assignment of lung (AXB_Lung) were compared to the values obtained when nasal cavity was reassigned to air (AXB_Air) under the dose-to-medium (D(m) ) reporting mode of AXB. RESULTS: For dose calculated under AXB_Lung, the D(98%) , D(2%) , and D(mean) of the PTV(69.96) _Air Cavity (PTV of prescription dose 69.96 Gy overlapping with nasal cavity) were on average 16.1%, 1.6%, and 8.6% larger than that calculated under AXB_Air, respectively. Up to 19.5% difference in D(98%) , 3% difference in D(2%) , and 11.2% difference in D(mean) were observed in the worst cases for PTV(69.96) . Similar trend was observed for the PTV(5940) _Air Cavity, in which the D(98%) , D(2%) , and D(mean) calculated under AXB_Lung were on average 14.7%, 2.5%, and 10.2% larger than that calculated under AXB_Air, respectively. In the worst cases, the difference observed in D(98%) , D(2%) , and D(mean) could be up to 17.7%, 4.5%, and 12.7%, respectively. CONCLUSIONS: Significant dose difference calculated by AXB between the material assignment of lung and air in nasal cavity for NPC cases might imply the possibility of underdosage to the PTVs that overlap with inhomogeneity. Therefore, attention should be put to ensure that accurate material assignment for dose calculation under AXB such that optimal dosage was given for tumor control. CI - (c) 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine. FAU - Cheung, Michael L M AU - Cheung MLM AD - Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China. FAU - Chow, Vivian U Y AU - Chow VUY AD - Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China. FAU - Kan, Monica W K AU - Kan MWK AD - Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China. AD - Department of Clinical Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China. FAU - Chan, Anthony T C AU - Chan ATC AD - Department of Clinical Oncology, Prince of Wales Hospital, Hong Kong SAR, China. AD - Department of Clinical Oncology, The Chinese University of Hong Kong, Hong Kong SAR, China. LA - eng PT - Journal Article DEP - 20220614 PL - United States TA - J Appl Clin Med Phys JT - Journal of applied clinical medical physics JID - 101089176 SB - IM MH - Algorithms MH - Humans MH - Nasal Cavity MH - Nasopharyngeal Carcinoma/radiotherapy MH - *Nasopharyngeal Neoplasms/radiotherapy MH - Phantoms, Imaging MH - Radiotherapy Dosage MH - Radiotherapy Planning, Computer-Assisted MH - *Radiotherapy, Intensity-Modulated PMC - PMC9359034 OTO - NOTNLM OT - Acuros XB algorithm OT - dose calculation OT - inhomogeneity OT - material assignment OT - nasopharyngeal carcinoma COIS- The authors declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported. EDAT- 2022/06/15 06:00 MHDA- 2022/08/11 06:00 PMCR- 2022/06/14 CRDT- 2022/06/14 06:52 PHST- 2022/04/21 00:00 [revised] PHST- 2022/02/16 00:00 [received] PHST- 2022/05/28 00:00 [accepted] PHST- 2022/06/15 06:00 [pubmed] PHST- 2022/08/11 06:00 [medline] PHST- 2022/06/14 06:52 [entrez] PHST- 2022/06/14 00:00 [pmc-release] AID - ACM213698 [pii] AID - 10.1002/acm2.13698 [doi] PST - ppublish SO - J Appl Clin Med Phys. 2022 Aug;23(8):e13698. doi: 10.1002/acm2.13698. Epub 2022 Jun 14.