PMID- 36294431 OWN - NLM STAT- PubMed-not-MEDLINE LR - 20221030 IS - 2077-0383 (Print) IS - 2077-0383 (Electronic) IS - 2077-0383 (Linking) VI - 11 IP - 20 DP - 2022 Oct 17 TI - The Feasibility of Whole-Liver Drainage with a Novel 8 mm Fully Covered Self-Expandable Metal Stent Possessing an Ultra-Slim Introducer for Malignant Hilar Biliary Obstructions. LID - 10.3390/jcm11206110 [doi] LID - 6110 AB - BACKGROUND: In the case of an unresectable malignant hilar biliary obstruction (MHBO), the optimal drainage method has not yet been established. Recently, an 8 mm, fully covered, self-expandable metal stent (FCSEMS) with an ultra-slim introducer has become available. In this article, the results of whole-liver drainage tests using this novel FCSEMS for MHBO are reported. METHODS: Unresectable MHBOs up to Bismuth IIIa with strictures limited to the secondary branches were eligible. The proximal end of the stent was placed in such a way as to avoid blocking the side branches, and the distal end was placed above the papilla when possible. Consecutive patients treated between April 2017 and January 2021 were retrospectively analyzed. The technical and functional success rates, rates and causes of recurrent biliary obstruction (RBO), time to RBO (TRBO), revision for RBO, and adverse events (AEs) were evaluated. RESULTS: Eleven patients (Bismuth I/II/IIIa: 1/7/3) were enrolled. Two stents were placed in nine patients and three were placed in two patients. Both the technical and functional success rates were 100%. RBO occurred in four (36%) patients due to sludge formation. Revision was performed for three patients, with the successful removal of all stents. The median TRBO was 187 days, and no late AEs other than the RBO occurred. Regarding the distal position of the stent, the RBO rate was significantly lower (14.3% vs. 75%, p = 0.041) and the cumulative TRBO was significantly longer (median TRBO: not reached vs. 80 days, p = 0.031) in the case of the placement above the papilla than the placement across the papilla. CONCLUSION: For unresectable MHBOs of Bismuth I, II, and IIIa, whole-liver drainage with a novel 8 mm FCSEMS possessing an ultra-slim introducer was feasible and potentially safe, with favorable stent patency. Placement above the papilla might be preferrable to placement across the papilla. FAU - Matsubara, Saburo AU - Matsubara S AD - Department of Gastroenterology and Hepatology, Saitama Medical Center, Saitama Medical University, Saitama 350-8550, Japan. FAU - Nakagawa, Keito AU - Nakagawa K AD - Department of Gastroenterology and Hepatology, Saitama Medical Center, Saitama Medical University, Saitama 350-8550, Japan. FAU - Suda, Kentaro AU - Suda K AD - Department of Gastroenterology and Hepatology, Saitama Medical Center, Saitama Medical University, Saitama 350-8550, Japan. FAU - Otsuka, Takeshi AU - Otsuka T AD - Department of Gastroenterology and Hepatology, Saitama Medical Center, Saitama Medical University, Saitama 350-8550, Japan. FAU - Oka, Masashi AU - Oka M AD - Department of Gastroenterology and Hepatology, Saitama Medical Center, Saitama Medical University, Saitama 350-8550, Japan. FAU - Nagoshi, Sumiko AU - Nagoshi S AD - Department of Gastroenterology and Hepatology, Saitama Medical Center, Saitama Medical University, Saitama 350-8550, Japan. LA - eng PT - Journal Article DEP - 20221017 PL - Switzerland TA - J Clin Med JT - Journal of clinical medicine JID - 101606588 PMC - PMC9605161 OTO - NOTNLM OT - endoscopic biliary drainage OT - fully covered self-expandable metal stent OT - malignant hilar biliary obstruction COIS- The authors declare no conflict of interest. EDAT- 2022/10/28 06:00 MHDA- 2022/10/28 06:01 PMCR- 2022/10/17 CRDT- 2022/10/27 01:30 PHST- 2022/08/31 00:00 [received] PHST- 2022/10/02 00:00 [revised] PHST- 2022/10/12 00:00 [accepted] PHST- 2022/10/27 01:30 [entrez] PHST- 2022/10/28 06:00 [pubmed] PHST- 2022/10/28 06:01 [medline] PHST- 2022/10/17 00:00 [pmc-release] AID - jcm11206110 [pii] AID - jcm-11-06110 [pii] AID - 10.3390/jcm11206110 [doi] PST - epublish SO - J Clin Med. 2022 Oct 17;11(20):6110. doi: 10.3390/jcm11206110.