PMID- 36626827 OWN - NLM STAT- MEDLINE DCOM- 20230123 LR - 20230320 IS - 1361-6498 (Electronic) IS - 0952-4746 (Linking) VI - 43 IP - 1 DP - 2023 Jan 20 TI - Dose reference level based on size-specific dose estimate (SSDE) and feasibility of deriving effective body diameter using tube current and time product (mAs) for adult chest and abdomen computed tomography (CT) procedures. LID - 10.1088/1361-6498/acb1bf [doi] AB - This study aimed to establish dose reference level (NDRLSSDE) based on size-specific dose estimate (SSDE) derived using effective diameter (Deff) for adult chest and abdomen computed tomography (CT) procedures and to explore the feasibility of drivingDeffusing the product of tube current and time (mAs). In this retrospective study, dose data, scan parameters and patient body dimensions at the mid-slice level from 14 CT units (out of 63 total) were extracted. Additionally, the mAs values of the axial slice at the samez-location where the diameter measurements were made (mAs(z)) were recorded. Pearson's correlation (r) analysis was used to determine the relationship ofDeffwith patient BMI, weight, and mAs(z). The NDRLSSDEfor the chest and abdomen were 9.72 mGy and 13.4 mGy, respectively. The BMI and body weight were less correlated (r= 0.24 andr= 0.33, respectively) withDeff. The correlation between mAs(z)andDeffwas considerably strong (r= 0.78) and can be used to predictDeffaccurately. The absolute dose differences between SSDEs calculated using the AAPM-204 method and mAs(z)was less than 1.1 mGy (15%). Therefore, mAs(z)is an efficient parameter to deriveDeff. Further, the direct conversion factors to estimate SSDEs at different locations along thez-direction in the scan region from corresponding mAs and CTDIvolwere calculated. The NDRLSSDEsuggested in the present study can be used as a reference for size-dependent dose optimisation in Sri Lanka, and existing NDRL based on CTDIvolunderestimate the average adult CT dose by 36.0% and 39.7% for chest and abdomen regions respectively. The results show that using mAs(z)to determine SSDE is a simple and practical approach with an accuracy of 95% and 85% for abdomen and chest scans, respectively. However, the obtained linear relationship betweenDeffand mAs is highly dependent on the ATCM technique and the user-determined noise levels of the scanning protocol. Finally, the phantom study resulted in the strongest correlation (r= 0.99) between theDwzand mAs(z), and the prediction of patient size would be more precise thanDeffmethod. CI - (c) 2023 Society for Radiological Protection. Published on behalf of SRP by IOP Publishing Limited. All rights reserved. FAU - Amalaraj, T AU - Amalaraj T AD - Department of Nuclear Science, University of Colombo, Colombo, Sri Lanka. FAU - Jeyasugiththan, Jeyasingam AU - Jeyasugiththan J AUID- ORCID: 0000-0003-2896-3768 AD - Department of Nuclear Science, University of Colombo, Colombo, Sri Lanka. FAU - Satharasinghe, Duminda AU - Satharasinghe D AUID- ORCID: 0000-0002-0269-2659 AD - Department of Nuclear Science, University of Colombo, Colombo, Sri Lanka. FAU - Pallewatte, A S AU - Pallewatte AS AD - Department of Radiology, National Hospital of Sri Lanka, Colombo, Sri Lanka. LA - eng PT - Journal Article DEP - 20230120 PL - England TA - J Radiol Prot JT - Journal of radiological protection : official journal of the Society for Radiological Protection JID - 8809257 SB - IM MH - Humans MH - Adult MH - Radiation Dosage MH - Retrospective Studies MH - Feasibility Studies MH - *Abdomen/diagnostic imaging MH - *Tomography, X-Ray Computed/methods OTO - NOTNLM OT - computed tomography (CT) OT - dose reference level (DRL) OT - effective diameter OT - mAs OT - size-specific dose estimate (SSDE) EDAT- 2023/01/11 06:00 MHDA- 2023/01/24 06:00 CRDT- 2023/01/10 17:32 PHST- 2022/09/04 00:00 [received] PHST- 2023/01/10 00:00 [accepted] PHST- 2023/01/11 06:00 [pubmed] PHST- 2023/01/24 06:00 [medline] PHST- 2023/01/10 17:32 [entrez] AID - 10.1088/1361-6498/acb1bf [doi] PST - epublish SO - J Radiol Prot. 2023 Jan 20;43(1). doi: 10.1088/1361-6498/acb1bf.