PMID- 36812877 OWN - NLM STAT- MEDLINE DCOM- 20230320 LR - 20230328 IS - 1879-2472 (Electronic) IS - 0049-3848 (Linking) VI - 224 DP - 2023 Apr TI - Estimating the measurement uncertainties of the international sensitivity index of 12 thromboplastins through Monte Carlo simulation. PG - 32-37 LID - S0049-3848(23)00046-4 [pii] LID - 10.1016/j.thromres.2023.02.007 [doi] AB - BACKGROUND: Measurement uncertainty (MU) estimation has become an important process in clinical laboratories; however, calculating the MUs of the international sensitivity index (ISI) of thromboplastins is difficult because of the complex mathematical calculations required in calibration. Therefore, this study quantifies the MUs of ISIs through the Monte Carlo simulation (MCS), which involves random sampling of numerical values to solve a complex mathematical calculation. METHODS: Eighty blood plasmas and commercially available certified plasmas (ISI Calibrate) were used to assign the ISIs of each thromboplastin. Prothrombin times were measured using reference thromboplastin and 12 commercially available thromboplastins (Coagpia PT-N, PT Rec, ReadiPlasTin, RecombiPlasTin 2G, PT-Fibrinogen, PT-Fibrinogen HS PLUS, Prothrombin Time Assay, Thromboplastin D, Thromborel S, STA-Neoplastine CI Plus, STA-Neoplastine R 15, and STA-NeoPTimal) with two automated coagulation instruments: ACL TOP 750 CTS (ACL TOP; Instrumentation Laboratory, Bedford, MA, USA) and STA Compact (Diagnostica Stago, Asnieres-sur-Seine, France). Then, the MUs of each ISI were simulated through MCS. RESULTS: The MUs of ISIs ranged from 9.7 % to 12.1 % and 11.6 % to 12.0 % when blood plasma and ISI Calibrate were used, respectively. For some thromboplastins, the ISI claimed by manufacturers significantly differed from the estimated results. CONCLUSIONS: MCS is adequate to estimate the MUs of ISI. These results would be clinically useful for estimating the MUs of the international normalized ratio in clinical laboratories. However, the claimed ISI significantly differed from the estimated ISI of some thromboplastins. Therefore, manufacturers should provide more accurate information about the ISI value of thromboplastins. CI - Copyright (c) 2023 Elsevier Ltd. All rights reserved. FAU - Lim, Yong Kwan AU - Lim YK AD - Department of Laboratory Medicine, Chung-Ang University College of Medicine, Seoul, South Korea. FAU - Kweon, Oh Joo AU - Kweon OJ AD - Department of Laboratory Medicine, Chung-Ang University College of Medicine, Seoul, South Korea. FAU - Lee, Mi-Kyung AU - Lee MK AD - Department of Laboratory Medicine, Chung-Ang University College of Medicine, Seoul, South Korea. FAU - Kim, Hye Ryoun AU - Kim HR AD - Department of Laboratory Medicine, Chung-Ang University College of Medicine, Seoul, South Korea. Electronic address: hyekim@cau.ac.kr. LA - eng PT - Journal Article DEP - 20230214 PL - United States TA - Thromb Res JT - Thrombosis research JID - 0326377 RN - 9035-58-9 (Thromboplastin) RN - 9001-32-5 (Fibrinogen) SB - IM MH - Humans MH - *Thromboplastin MH - Monte Carlo Method MH - Uncertainty MH - Prothrombin Time MH - International Normalized Ratio/methods MH - *Fibrinogen MH - Calibration OTO - NOTNLM OT - International normalized ratio OT - International sensitivity index OT - Measurement uncertainty OT - Monte Carlo simulation OT - Prothrombin time OT - Thromboplastin COIS- Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. EDAT- 2023/02/23 06:00 MHDA- 2023/03/21 06:00 CRDT- 2023/02/22 18:19 PHST- 2022/08/29 00:00 [received] PHST- 2023/02/09 00:00 [revised] PHST- 2023/02/10 00:00 [accepted] PHST- 2023/02/23 06:00 [pubmed] PHST- 2023/03/21 06:00 [medline] PHST- 2023/02/22 18:19 [entrez] AID - S0049-3848(23)00046-4 [pii] AID - 10.1016/j.thromres.2023.02.007 [doi] PST - ppublish SO - Thromb Res. 2023 Apr;224:32-37. doi: 10.1016/j.thromres.2023.02.007. Epub 2023 Feb 14.