PMID- 36966773 OWN - NLM STAT- MEDLINE DCOM- 20230501 LR - 20230916 IS - 1473-5687 (Electronic) IS - 0954-691X (Linking) VI - 35 IP - 5 DP - 2023 May 1 TI - Accuracy and concordance of two-dimensional shear-wave elastography using transient elastography as the reference in chronic viral hepatitis and HIV infection in Rio de Janeiro, Brazil. PG - 583-590 LID - 10.1097/MEG.0000000000002537 [doi] AB - OBJECTIVES: Evaluate the accuracy and agreement of two-dimensional shear-wave elastography (2D-SWE) LOGIQ-S8 with transient elastography in patients from Rio de Janeiro, Brazil. METHOD: This retrospective study compared liver stiffness measurements (LSMs) using transient elastography (M and XL probes) and 2D-SWE GE-LOGIQ-S8 performed by a single experienced operator on the same day in 348 consecutive individuals with viral hepatitis or HIV infection. Suggestive and highly suggestive compensated-advanced chronic liver disease (c-ACLD) were defined by transient elastography-LSM >/=10 kPa and >/=15 kPa, respectively. Agreement between techniques and accuracy of 2D-SWE using transient elastography-M probe as the reference was assessed. Optimal cut-offs for 2D-SWE were identified using the maximal Youden index. RESULTS: Three hundred five patients [61.3% male, median age = 51 [interquartile range (IQR), 42-62] years, 24% with hepatitis C virus (HCV) +/- HIV; 17% with hepatitis B virus (HBV) +/- HIV; 31% were HIV mono-infected and 28% had HCV +/- HIV post-sustained virological response] were included. The overall correlation (Spearman's rho ) was moderate between 2D-SWE and transient elastography-M ( rho = 0.639) and weak between 2D-SWE and transient elastography-XL ( rho = 0.566). Agreements were strong ( rho > 0.800) in people with HCV or HBV mono-infection, and poor in HIV mono-infected ( rho > 0.400). Accuracy of 2D-SWE for transient elastography-M >/= 10 kPa [area under the receiver operating characteristic (AUROC) = 0.91 (95% confidence interval [CI], 0.86-0.96); optimal cut-off = 6.4 kPa, sensitivity = 84% (95% CI, 72-92), specificity = 89% (95% CI, 84-92)] and for transient elastography-M >/= 15 kPa [AUROC = 0.93 (95% CI, 0.88-0.98); optimal cut-off = 7.1 kPa; sensitivity = 91% (95% CI, 75-98), specificity = 89% (95% CI, 85-93)] were excellent. CONCLUSION: 2D-SWE LOGIQ-S8 system had a good agreement with transient elastography and an excellent accuracy to identify individuals at high risk for c-ACLD. CI - Copyright (c) 2023 Wolters Kluwer Health, Inc. All rights reserved. FAU - Coelho, Mariana AU - Coelho M AD - Laboratory of Clinical Research in STD/AIDS (LAPCLIN-AIDS), Oswaldo Cruz Foundation (FIOCRUZ), National Institute of Infectious Diseases Evandro Chagas (INI). FAU - Fernandes, Flavia AU - Fernandes F AD - Hepatology Department, Bonsucesso Federal Hospital. FAU - Cardoso, Sandra W AU - Cardoso SW AD - Laboratory of Clinical Research in STD/AIDS (LAPCLIN-AIDS), Oswaldo Cruz Foundation (FIOCRUZ), National Institute of Infectious Diseases Evandro Chagas (INI). FAU - Piedade, Juliana AU - Piedade J AD - Hepatology Department, Bonsucesso Federal Hospital. AD - Estacio de Sa University, School of Medicine, Rio de Janeiro, Brazil. FAU - Torres da Silva, Marcos Vinicius AU - Torres da Silva MV AD - Laboratory of Clinical Research in STD/AIDS (LAPCLIN-AIDS), Oswaldo Cruz Foundation (FIOCRUZ), National Institute of Infectious Diseases Evandro Chagas (INI). FAU - Santos, Ricardo AU - Santos R AD - Laboratory of Clinical Research in STD/AIDS (LAPCLIN-AIDS), Oswaldo Cruz Foundation (FIOCRUZ), National Institute of Infectious Diseases Evandro Chagas (INI). FAU - Veloso, Valdilea G AU - Veloso VG AD - Laboratory of Clinical Research in STD/AIDS (LAPCLIN-AIDS), Oswaldo Cruz Foundation (FIOCRUZ), National Institute of Infectious Diseases Evandro Chagas (INI). FAU - Grinsztejn, Beatriz AU - Grinsztejn B AD - Laboratory of Clinical Research in STD/AIDS (LAPCLIN-AIDS), Oswaldo Cruz Foundation (FIOCRUZ), National Institute of Infectious Diseases Evandro Chagas (INI). FAU - Pereira, Gustavo Henrique AU - Pereira GH AD - Hepatology Department, Bonsucesso Federal Hospital. AD - Estacio de Sa University, School of Medicine, Rio de Janeiro, Brazil. FAU - Perazzo, Hugo AU - Perazzo H AD - Laboratory of Clinical Research in STD/AIDS (LAPCLIN-AIDS), Oswaldo Cruz Foundation (FIOCRUZ), National Institute of Infectious Diseases Evandro Chagas (INI). LA - eng PT - Journal Article DEP - 20230318 PL - England TA - Eur J Gastroenterol Hepatol JT - European journal of gastroenterology & hepatology JID - 9000874 SB - IM MH - Humans MH - Male MH - Middle Aged MH - Female MH - Liver Cirrhosis/diagnostic imaging MH - Retrospective Studies MH - *Elasticity Imaging Techniques/methods MH - Brazil/epidemiology MH - *HIV Infections/complications MH - *Liver Diseases MH - Hepatitis, Chronic MH - *Hepatitis C MH - *Hepatitis B MH - Hepatitis B virus MH - Liver/diagnostic imaging EDAT- 2023/03/27 06:00 MHDA- 2023/05/01 06:42 CRDT- 2023/03/26 19:53 PHST- 2023/05/01 06:42 [medline] PHST- 2023/03/27 06:00 [pubmed] PHST- 2023/03/26 19:53 [entrez] AID - 00042737-202305000-00010 [pii] AID - 10.1097/MEG.0000000000002537 [doi] PST - ppublish SO - Eur J Gastroenterol Hepatol. 2023 May 1;35(5):583-590. doi: 10.1097/MEG.0000000000002537. Epub 2023 Mar 18.