PMID- 37361026 OWN - NLM STAT- PubMed-not-MEDLINE LR - 20240129 IS - 0219-5194 (Print) IS - 1793-6810 (Electronic) IS - 0219-5194 (Linking) VI - 23 IP - 3 DP - 2023 Jan 28 TI - AGREEMENT OF HIP KINEMATICS BETWEEN TWO TRACKING MARKER CONFIGURATIONS USED WITH THE CODA PELVIS DURING ERGONOMIC ROOFING TASKS. LID - 10.1142/s021951942350015x [doi] AB - The anterior and posterior iliac spine markers frequently used to define the pelvis, are commonly occluded during three-dimensional (3D) motion capture. The occlusion of these markers leads to the use of various tracking marker configurations on the pelvis, which affect kinematic results. The purpose of this investigation was to examine the agreement of CODA pelvis kinematic results when two different tracking marker configurations were used during roofing tasks. 3D motion data were collected on seven male subjects while mimicking two roofing tasks. Hip joint angles (HJAs) were computed using the CODA pelvis with two different tracking marker configurations, the trochanter tracking method (TTM), and virtual pelvis tracking method (VPTM). Agreement between tracking marker configurations was assessed using cross-correlations, bivariate correlations, mean absolute differences (MADs), and Bland-Altman (BA) plots. The correlations displayed no time lag and strong agreement (all r > 0.83) between the HJA from the VPTM and TTM, suggesting the timing occurrence of variables are comparable between the two tracking marker configurations. The MAD between the VPTM and TTM displayed magnitude differences, but most of the differences were within a clinically acceptable range. Caution should still be used when comparing kinematic results between various tracking marker configurations, as differences exist. FAU - Moore, Kevin D AU - Moore KD AD - Health Effects Laboratory Division, National Institute for Occupational Safety & Health, Centers for Disease Control and Prevention, 1095 Willowdale Rd., Morgantown West Virginia 26505, USA. FAU - Hawke, Ashley L AU - Hawke AL AD - Health Effects Laboratory Division, National Institute for Occupational Safety & Health, Centers for Disease Control and Prevention, 1095 Willowdale Rd., Morgantown West Virginia 26505, USA. FAU - Carey, Robert E AU - Carey RE AD - Health Effects Laboratory Division, National Institute for Occupational Safety & Health, Centers for Disease Control and Prevention, 1095 Willowdale Rd., Morgantown West Virginia 26505, USA. FAU - Wu, John Z AU - Wu JZ AD - Health Effects Laboratory Division, National Institute for Occupational Safety & Health, Centers for Disease Control and Prevention, 1095 Willowdale Rd., Morgantown West Virginia 26505, USA. FAU - Breloff, Scott P AU - Breloff SP AD - Health Effects Laboratory Division, National Institute for Occupational Safety & Health, Centers for Disease Control and Prevention, 1095 Willowdale Rd., Morgantown West Virginia 26505, USA. LA - eng GR - CC999999/ImCDC/Intramural CDC HHS/United States PT - Journal Article PL - United States TA - J Mech Med Biol JT - Journal of mechanics in medicine and biology JID - 101134377 PMC - PMC10285509 MID - NIHMS1899605 OTO - NOTNLM OT - Tracking markers OT - ergonomics OT - kinematics OT - motion capture OT - pelvis OT - technical markers EDAT- 2023/06/26 19:07 MHDA- 2023/06/26 19:08 PMCR- 2024/01/28 CRDT- 2023/06/26 12:46 PHST- 2023/06/26 19:08 [medline] PHST- 2023/06/26 19:07 [pubmed] PHST- 2023/06/26 12:46 [entrez] PHST- 2024/01/28 00:00 [pmc-release] AID - 10.1142/s021951942350015x [doi] PST - ppublish SO - J Mech Med Biol. 2023 Jan 28;23(3):10.1142/s021951942350015x. doi: 10.1142/s021951942350015x.